A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Suzuki, S.

  
Paper Title Page
MOPKF046 Photoelectron RF Gun Designed as a Single Cell Cavity 411
 
  • H. Dewa, T. Asaka, H. Hanaki, T. Kobayashi, A. Mizuno, S. Suzuki, T. Taniuchi, H. Tomizawa, K. Yanagida
    JASRI/SPring-8, Hyogo
  • J. Sasabe
    Hamamatsu Photonics K.K., Hamakita, Shizuoka
  • M. Uesaka
    UTNL, Ibaraki
 
  The paper describes the recent improvements of S-band RF-gun at SPring-8. The cavity of the gun is a single-cell pillbox, and the copper inner wall is used as a cathode. The electron beam from the cathode was accelerated up to 4.1 MeV at an electric field of 175 MV/m. For emittance compensation, two solenoid magnets were used. A 3m linac and a quadrupole scan emittance diagnostic were added after the RF-gun. The beam energy spread and beam emittance after the linac is presented. The beam emittance measured with quadrupole scan is compered to that measured with double slits just after the RF-gun. For high quantum efficiency, Cs2Te cathode was also tested. It is vacuum sealed in a cartridge-type electric tube and four tubes can be installed in a vacuum chamber behind the cavity. Although the quantum efficiency after RF conditioning for two hours to achieve 90MV/m was 3%, it decreased to 1% after the 28 hours RF conditioning.  
TUPLT074 Dark Current Reduction System for SPring-8 Linac 1324
 
  • T. Kobayashi, T. Asaka, H. Hanaki, M. Shoji, S. Suzuki, K. Tamura
    JASRI/SPring-8, Hyogo
 
  The SPring-8 linac accelerates dark currents generated by its injector part up to 1 GeV. These dark currents are injected with main beam into the SPring-8 storage ring and then spoil the purity of the stored beam. The dark currents are mainly composed of a grid emission current from a thermionic gun and field emission currents from rf accelerating structures. A beam deflector for kicking only the grid emission by a pulsed electric field was developed and installed in the SPring-8 linac. We observed that the beam deflector greatly reduced the grid emission current accelerated up to 1 GeV. The measured purity of the stored single-bunched beam was about 5x10-6 when the deflector operated, which was almost 1/100 of the purity without filtering by the deflector. However, the deflector, which is installed before the prebucher, cannot reduced the field emission currents from the buncher cavities and the first acccelerating structure. These dark currents take considerable proportion of the total dark currents observed at the end of the linac. We are trying to spin off the field emission currents by weak magnetic fields across the accelerating structure generated by several coils.  
TUPLT075 Improvements of SPring-8 Linac towards Top-up Operation 1327
 
  • S. Suzuki, T. Asaka, H. Dewa, H. Hanaki, T. Kobayashi, T. Masuda, A. Mizuno, T. Taniuchi, H. Tomizawa, K. Yanagida
    JASRI/SPring-8, Hyogo
 
  The top-up operation of the SPring-8 storage ring will start in May, 2004. In order to realize alternative injection into the booster synchrotron in the top-up operation and the NewSUBARU, an AC bending magnet replaced the DC bending magnet in the beam transport line to the booster synchrotron. This magnet operates at 1 Hz with a trapezoid current pattern. The 1-GeV electron beam goes at the bottom of the current pattern to the NewSUBARU or at the top of the pattern to the booster synchrotron. In order to obtain the higher reliability of the linac for the top-up operation, reinforcement of the beam monitor systems, further improvement of RF phase stability and upgrade of the control system were required. BPM?s has been newly installed in energy dispersion sections, and beam transport feedback control is in development. The phase variation in the RF system was reduced by the regulation of the gas pressure in the waveguide of the klystrons drive system. We re-engineered the VME systems to maximize availability of the linac operation considering its reliability, usability, expandability and flexibility.  
THOACH03 Top-up Operation at SPring-8 - Towards Maximizing the Potential of a 3rd Generation Light Source 222
 
  • H. Tanaka, T. Aoki, T. Asaka, S. Daté, K. Fukami, Y. Furukawa, H. Hanaki, N. Hosoda, T. Kobayashi, N. Kumagai, M. Masaki, T. Masuda, S. Matsui, A. Mizuno, T. Nakamura, T. Nakatani, T. Noda, T. Ohata, H. Ohkuma, T. Ohshima, M. Oishi, S. Sasaki, J. Schimizu, M. Shoji, K. Soutome, M. Suzuki, S. Suzuki, S. Takano, M. Takao, T. Takashima, H. Takebe, K. Tamura, R. Tanaka, T. Taniuchi, Y. Taniuchi, K. Tsumaki, A. Yamashita, K. Yanagida, H. Yonehara, T. Yorita
    JASRI/SPring-8, Hyogo
  • M. Adachi, K. Kobayashi, M. Yoshioka
    SES, Hyogo-pref.
 
  Top-up operation maximizes research activities in a light source facility by an infinite beam lifetime and photon beam stability. We have been improving the SPring-8 accelerators to achieve the ideal top-up operation. For the perturbation-free injection, we adjusted the magnetic field shape of four bump magnets to close the bump orbit, and introduced a scheme to suppress the stored beam oscillation induced by the nonlinearlity of sextupole magnets. These reduced the horizontal oscillation down to a third of the stored beam size. For the loss-free injection, beam collimators were installed upstream of the injection line. This realized the injection efficiency of ~100% under the restricted gap condition of in-vacuum insertion devices (ID). Since autumn 2003, we have been injecting the beams keeping the photon beam shutters opened and ID gaps closed. We developed a bunch-by-bunch feedback system to reduce the beam loss further with all the ID gaps fully closed by lowering the operating chromaticity. The operation with constant stored current is scheduled in June 2004. We present the overview and progress of the SPring-8 top-up operation focusing on our developments and results.  
Video of talk
Transparencies
WEPKF039 The Vacuum System of Super SOR 1690
 
  • H. Sakai, M. Fujisawa, A. Kakizaki, T. Kinishita, H. Kudo, N. Nakamura, O. Okuda, S. Shibuya, K. Shinoe, H. Takaki
    ISSP/SRL, Chiba
  • K. Kobayashi
    KEK, Ibaraki
  • T. Koseki
    RIKEN/RARF/BPEL, Saitama
  • H. Ohkuma
    JASRI/SPring-8, Hyogo
  • S. Suzuki
    LNS, Sendai
 
  The Super-SOR light source is a Japanese VUV and soft X-ray third-generation synchrotron radiation source, which consists of 1.8GeV storage ring and injector. The beam current is circulated up to 400mA. These accelerators are designed so as to fully meet requirements for top-up injection. In order to realize these operation modes, our vacuum system are required on following conditions. One is to obtain the long lifetime. The other is not to melt the vacuum chamber by irradiating the high flux synchrotron radiation. Finally beam instability is not occurred by large wake fields. We describe the design of the vaccum chamber of Super-SOR and present the recent R&D concerning this system.