A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Geng, H.

Paper Title Page
TUPE049 Optimisation of an HHG-Seeded Harmonic Cascade FEL Design for the NLS Project 2254
 
  • D.J. Dunning, N. Thompson
    STFC/DL/ASTeC, Daresbury, Warrington, Cheshire
  • R. Bartolini
    JAI, Oxford
  • H. Geng, Z. Huang
    SLAC, Menlo Park, California
  • B.W.J. McNeil
    USTRAT/SUPA, Glasgow
 
 

Optimisation studies of an HHG-seeded harmonic cascade FEL design for the UK's proposed New Light Source (NLS) facility are presented. Three separate FELs are planned to meet the requirements for continuous coverage of the photon energy range 50-1000 eV with variable polarisation, 20 fs pulse widths and good temporal coherence. The design uses an HHG seed source tuneable from 50-100 eV to provide direct FEL seeding in this range, and one or two stage harmonic cascades to reach the higher photon energies. Studies have been carried out to optimise a harmonic cascade FEL operating at 1 keV; topics investigated include modulator configuration, seed power level and effects of the HHG seed structure. FEL simulations using realistic electron beam distributions are presented and tolerance to increased emittance has been considered.

 
TUPE068 Polarization Analysis for Seeded FELs in a Crossed-Planar Undulator 2290
 
  • H. Geng, Y.T. Ding, Z. Huang
    SLAC, Menlo Park, California
  • R. Bartolini
    Diamond, Oxfordshire
  • D.J. Dunning, N. Thompson
    STFC/DL/ASTeC, Daresbury, Warrington, Cheshire
 
 

The crossed-planar undulator is a promising scheme for full polarization control in an x-ray FEL*. For SASE FELs, it has been shown a maximum degree of circular polarization of about 80% is achievable**. In this paper, we study the effectiveness of a cross undulator for a seeded x-ray FEL. The degree of circular polarization for both the fundamental and the harmonic radiation are considered.


* K.-J. Kim, Nucl. Instrum. Methods A445, 329 (2000).
** Y. Ding, Z. Huang, Phys. Rev. ST-AB 11, 030702 (2008).

 
TUPE036 The Parameter Study for the Enhanced High Gain Harmonic Generation Scheme 2221
 
  • Q.K. Jia, H. Geng, H.T. Li
    USTC/NSRL, Hefei, Anhui
 
 

An easy-to-implement scheme called Enhanced High Gain Harmonic Generation has been proposed and shown to be able to significantly enhance the performance of traditional HGHG-FEL. In this paper we investigate the effects of the system parameters in EHGHG scheme, such as the electron energy tuning, the energy spread, the dispersive strength, amount of the phase shift, and the power of seed laser. The numerical results are presented, and shown that: the EHGHG scheme has acceptable the parameters tolerance requirements and is not more or even less sensitive to the system parameters than that of the existing scheme.

 
THPE006 Closed Orbit Correction of Hefei Light Source (HLS) Upgrading Storage Ring 4521
 
  • S.C. Zhang, W. Fan, G. Feng, W.W. Gao, H. Geng, Z.G. He, W. Li, L. Wang, H. Xu
    USTC/NSRL, Hefei, Anhui
 
 

In order to meet the increasing requirements of synchrotron radiation users, an upgrading plan of hefei light source is undergoing by National Synchrotron Radiation Laboratory (NSRL). The emittance of storage ring is reduced from 166nm.rad to 36nm.rad. In this paper, we study the beam close orbit distortions' (COD) sensitivity to the field and alignment errors in magnets. Estimation of the COD from various error sources is investigated. The distribution of beam position monitors and the location of correctors are reported in the paper. Simulation proves that COD can be corrected down to 50 microns level. In the same time the corrector strengths are weaker enough in the correction scheme.