       <titles>
          <title>
             First Results of the IFMIF/EVEDA-SaTHoRI Tests
          </title>
       </titles>
		 <publisher>JACoW</publisher>
       <pub-location>Geneva, Switzerland</pub-location>
		 <isbn>978-3-95450-191-5</isbn>
		 <electronic-resource-num>10.18429/JACoW-SRF2017-MOPB086</electronic-resource-num>
		 <language>English</language>
		 <pages>262-265</pages>
       <pages>MOPB086</pages>
       <keywords>
          <keyword>ion</keyword>
          <keyword>cavity</keyword>
          <keyword>SRF</keyword>
          <keyword>controls</keyword>
          <keyword>cryomodule</keyword>
       </keywords>
       <work-type>Contribution to a conference proceedings</work-type>
       <dates>
          <year>2018</year>
          <pub-dates>
             <date>2018-01</date>
          </pub-dates>
       </dates>
       <urls>
          <related-urls>
              <url>https://doi.org/10.18429/JACoW-SRF2017-MOPB086</url>
              <url>http://jacow.org/srf2017/papers/mopb086.pdf</url>
          </related-urls>
       </urls>
       <abstract>
          The SaTHoRI test stand (Satellite de Tests Horizontal des Résonateurs IFMIF) aims to characterize a jacketed and fully dressed cavity with its coupler and tuner. A dedicated test cryostat has been manufactured and is connected to an existing horizontal test cryostat which provides the cryogenic coolant. A RF source ' provided by the IFMIF collaboration, one of the four RF sources which will be used for the cryomodule at Rokkasho ' has been installed and commissioned at CEA. This paper describes the test stand and presents the first results.