<xml>
  <records>
    <record>
       <contributors>
          <authors>
             <author>Chen, L.</author>
             <author>Chang, W.</author>
             <author>Jiang, T.C.</author>
             <author>Li, C.L.</author>
             <author>Li, Y.M.</author>
             <author>Wang, R.X.</author>
             <author>Zhang, S.H.</author>
          </authors>
       </contributors>
       <titles>
          <title>
             The Development of the LLRF Control System for the New High Power Test Stand of Couplers
          </title>
       </titles>
		 <publisher>JACoW</publisher>
       <pub-location>Geneva, Switzerland</pub-location>
		 <isbn>978-3-95450-191-5</isbn>
		 <electronic-resource-num>10.18429/JACoW-SRF2017-MOPB072</electronic-resource-num>
		 <language>English</language>
		 <pages>227-230</pages>
       <pages>MOPB072</pages>
       <keywords>
          <keyword>ion</keyword>
          <keyword>vacuum</keyword>
          <keyword>controls</keyword>
          <keyword>LLRF</keyword>
          <keyword>FPGA</keyword>
       </keywords>
       <work-type>Contribution to a conference proceedings</work-type>
       <dates>
          <year>2018</year>
          <pub-dates>
             <date>2018-01</date>
          </pub-dates>
       </dates>
       <urls>
          <related-urls>
              <url>https://doi.org/10.18429/JACoW-SRF2017-MOPB072</url>
              <url>http://jacow.org/srf2017/papers/mopb072.pdf</url>
          </related-urls>
       </urls>
       <abstract>
          RF power conditioning is an effective way to suppress multipacting in fundamental mode power couplers. Room temperature test-stand conditioning is an essential step that can be hardly circumvented before couplers are installed on SC cavities. Based on our original one, a new test-stand has been designed and being assembled at IMP. It can work as a multi-task platform conditioning different couplers, including couplers for HWR010 cavities and HWR015 cavities. It is also featured with the capacity to flexibly change β according to different specifications. A variety of conditioning modes have been incorporated into the LLRF system, including frequency sweeping mode, amplitude sweeping mode, arbitrary-duty-cycle mode and triangle-wave mode. In addition, smartly-conditioning has been achieved because of the accomplishment of smart interlocks and automatic reset in the system.
       </abstract>
    </record>
  </records>
</xml>