A  B  C  D  E  F  G  H  I  J  K  L  M  N  O  P  Q  R  S  T  U  V  W  X  Y  Z  

Reilly J.

PaperTitlePage
WEP26High power tests of input couplers for Cornell ERL injector517
 
  • V. Veshcherevich, S. Belomestnykh, P. Quigley, J. Reilly, J. Sears
    Cornell University
 
 RF power couplers for the ERL injector, currently under construction at Cornell University, have been fabricated. The couplers were assembled in pairs in the liquid nitrogen cryostat, built for their tests. First two prototype couplers were tested using an IOT transmitter and a resonant ring for additional power amplification. They were tested up to the goal power level of 50 kW CW and used later for tests of the first injector cavity. However, the first pair of couplers showed excessive temperature rise in some points. Therefore, minor changes in the design have been done to improve cooling. The couplers of updated design were successfully tested from a klystron up to the power level of 60 kW CW. In situ baking was implemented for coupler installed in the cryostat.