Paper | Title | Page |
---|
TUP47 | Diagnostic Instrumentation for the Fermilab Vertical Cavity Test Facility | 235 |
| - C. M. Ginsburg, R. Carcagno, M. Champion, N. Dhanaraj, A. Lunin, A. Mukherjee, R. Nehring, D. Orris, J. P. Ozelis, V. Poloubotko, D. A. Sergatskov
Fermilab - W. -D. Moeller
DESY
| |
| We describe the design and initial test results of the
Fermilab vertical cavity test facility (VCTF) diagnostic
instrumentation which is used to understand cavity
performance, including thermometry to detect hot spots
caused by quenches or field emission, and a variable RF
input coupler to facilitate the TM010 passband mode
measurements used to isolate poorly performing cells. | |
WEP15 | Initial results from Fermilab's vertical test stand for SRF cavities | 472 |
| - J. P. Ozelis, R. Carcagno, C. M. Ginsburg, Y. Huang, R. Nehring, B. Norris, V. Poloubotko, R. Rabehl, I. Rakhno, C. Reid, T. Peterson, D. A. Sergatskov, C. Sylvester, M. Wong, C. Worel, A. Yuan
Fermilab - C. Grenoble, T. J. Powers
TJNAF
| |
| Fermilab has constructed a facility for vertical testing
of SRF cavities, operating at a nominal temperature of
2K, to be used as part of the global International Linear
Collider (ILC) effort to improve cavity processing and
performance reproducibility. Following successful
cryogenic commissioning, the first tests of single cell and
9-cell ILC-style cavities were performed. These first test
results are presented in detail, along with a brief
discussion of present measurement accuracy. | |