| Paper | Title | Page |
|---|---|---|
| TUA02 | Current Status of VEPP-5 Injection Complex | 37 |
|
||
| VEPP-5 Injection Complex (IC) supplies VEPP-2000 and VEPP-4 colliders at Budker Institute of Nuclear Physics (BINP, Russia) with high energy electron and positron beams. Since 2016 the IC has shown the ability to support operation of both colliders routinely with maximum positron storage rate of 1.7·1010 e+/s. Stable operation at the energy of 430 MeV has been reached. Research on further improvements on the IC performance is carried out. In particular control system was improved, additional beam diagnostics systems were developed, monitoring of RF system was upgraded. In this paper, the latest achieved IC performance, operational results and prospects are presented. | ||
|
|
Slides TUA02 [2.966 MB] | |
| DOI • | reference for this paper ※ doi:10.18429/JACoW-RuPAC2021-TUA02 | |
| About • | Received ※ 28 September 2021 — Revised ※ 01 October 2021 — Accepted ※ 09 October 2021 — Issued ※ 11 October 2021 | |
| Cite • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
| WEA03 | 200 MeV Linac Development for the SKIF Light Source Injector | 68 |
|
||
| A new synchrotron light source SKIF of the 4th gen-eration is construction at Budker institute of nuclear physics (Novosibirsk, Russia). It consists of the main ring, the booster ring and the linear accelerator. This paper presents design of the linear accelerator which is expected to provide electron beams with the energy of 200 MeV. Construction of the linear accelerator is discussed. Description of the linear accelerator main systems is presented. | ||
|
|
Slides WEA03 [4.794 MB] | |
| DOI • | reference for this paper ※ doi:10.18429/JACoW-RuPAC2021-WEA03 | |
| About • | Received ※ 20 September 2021 — Revised ※ 01 October 2021 — Accepted ※ 09 October 2021 — Issued ※ 16 October 2021 | |
| Cite • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THB01 |
Precise Generation and Distribution System of RF Reference Signal for SKIF Accelerator Complex | |
|
||
| A clean and precise RF reference signal is needed at different locations of a particle accelerator complex to synchronize the different accelerating structures and for other applications. Proper synchronization can only be achieved if the RF reference signal fulfills strict quality parameters in terms of jitter and long-term stability. The precise RF reference signal will be needed also in the case of the SKIF accelerator complex, which is being built by BINP in Novosibirsk. In this case, the reference signal stability of down to <1 ps is required. The design and development of the system for the generation and distribution of the precise RF reference signal at the SKIF complex are presented in this paper. The system comprises a reference master oscillator, distribution amplifiers, which also support the generation of higher harmonics of the RF signal, and optical transfer systems for the transfer of the RF signals over longer distances. Test results obtained with prototypes are also reported. | ||
|
|
Slides THB01 [6.205 MB] | |
| Cite • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |