Author: Reinhardt-Nickoulin, P.I.
Paper Title Page
WEPPD055 Emittance Measurements at the Exit of INR Linac 668
 
  • P.I. Reinhardt-Nickoulin, S. Bragin, A. Feschenko, S.A. Gavrilov, N.F. Lebedeva, A.N. Mirzojan, A.N. Naboka, I.V. Vasilyev, O. Volodkevich
    RAS/INR, Moscow, Russia
 
  Emittance measurements at the exit of INR linac are of importance for proper beam matching with the beam line of the downstream experimental facility. Emittance ellipses are reconstructed from beam profile data obtained with three wire scanners and one ionization beam cross section monitor (BCSM). A possibility of quadrupole gradients adjustment not only increases the reconstruction accuracy but also enables to find emittances with BCSM data only. The latter provides completely transparent measurements and due to large BCSM range can be done within a wide range of beam currents. The results of measurements done with wire scanners and BCSM are presented and compared, the reconstruction procedure features are discussed.  
 
WEPPD056 Development of INR Linac BCT System 671
 
  • P.I. Reinhardt-Nickoulin, S. Bragin, V. Gaidash, O.V. Grekhov, Yu.V. Kiselev, N.F. Lebedeva, A.N. Mirzojan, A.N. Naboka, I.V. Vasilyev, O. Volodkevich
    RAS/INR, Moscow, Russia
 
  New electronics of automatic BCT system was developed to provide beam intensity measurements along INR linac. BCT electronics details are described. The available results of beam measurements are given.