WEPPD055 | Emittance Measurements at the Exit of INR Linac | 668 |
|
||
Emittance measurements at the exit of INR linac are of importance for proper beam matching with the beam line of the downstream experimental facility. Emittance ellipses are reconstructed from beam profile data obtained with three wire scanners and one ionization beam cross section monitor (BCSM). A possibility of quadrupole gradients adjustment not only increases the reconstruction accuracy but also enables to find emittances with BCSM data only. The latter provides completely transparent measurements and due to large BCSM range can be done within a wide range of beam currents. The results of measurements done with wire scanners and BCSM are presented and compared, the reconstruction procedure features are discussed. | ||