The vacuum monitoring system of Kurchatov Center of Synchrotron Radiation is built on current measuring of sputter ion pumps mounted over vacuum chambers of accelerating units. Measuring hardware designed in INP SB RAS is using CAMAC standard and has been operating for a decade now. Hardware upgrade is accomplished by installing a PC workstation, connected through CAN bus to an in-house crate controller. Developed software comprises three levels. Firstly, there is a low-level program running inside the crate controller under RTX-166 operational system. Secondly, we have SQL Server database with client program, whose function is to create the queries at workstation side. And finally there are high-level applications running over network needed to display a current facility status and a data processing.