A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Yang, B.X.

Paper Title Page
MPPE066 Streak Camera Studies of Vertical Synchro-Betatron-Coupled Electron Beam Motion in the APS Storage Ring 3694
 
  • B.X. Yang, M. Borland, W. Guo, K.C. Harkay, V. Sajaev
    ANL, Argonne, Illinois
 
  Funding: Work supported by U.S. Department of Energy, Office of Basic Energy Sciences under Contract No. W-31-109-ENG-38.

We present experimental studies of synchro-betatron-coupled electron beam motion in the Advanced Photon Source storage ring. We used a vertical kicker to start the beam motion. When the vertical chromaticity is nonzero, electrons with different initial synchrotron phases have slightly different betatron frequencies from the synchronous particle, resulting in a dramatic progression of bunch-shape distortion. Depending on the chromaticity and the time following the kick, images ranging from a simple vertical tilt in the bunch to more complicated twists and bends are seen with a visible light streak camera. Turn-by-turn beam position monitor data were taken as well. We found that the experimental observations are well described by the synchro-betatron-coupled equations of motion. We are investigating the potential of using the tilted bunch to generate picosecond x-ray pulses. Also note that the fast increase in vertical beam size after the kick is dominated by the internal synchro-betatron-coupled motion of the electron bunch. Experimentally this increase could be easily confused with decoherence of vertical motion if the bunch is only imaged head-on.

 
MPPP035 Investigation of APS PAR Vertical Beam Instability 2393
 
  • C. Yao, Y.-C. Chae, N. Sereno, B.X. Yang
    ANL, Argonne, Illinois
 
  Funding: This work is supported by the U.S. Department of Energy, Office of Basic Energy Sciences, under Contract No. W-31-109-ENG-38.

The Advanced Photon Source (APS) particle accumulator ring (PAR) is a 325-MeV storage ring that collects and compresses linac pulse trains into a single bunch for booster injection. A vertical beam instability has been observed when only a single linac bunch is injected and the total beam charge is from 0.15 to 0.7 nC. The instability starts about 80 ms after the injection, lasts about 160 ms, and is highly reproducible. We performed spectral measurement and time-resolved imaging with both a gated-intensified camera and a streak camera in order to characterize this instability. Initial analysis of the data indicates that the instability is due to ion trapping. A stable lattice was established as result of the investigation. This report summarizes the experimental results and gives some preliminary analysis.

 
TOPC001 Visualizing Electron Beam Dynamics and Instabilities with Synchrotron Radiation at the APS 74
 
  • B.X. Yang, A.H. Lumpkin
    ANL, Argonne, Illinois
 
  Funding: Work supported by U.S. Department of Energy, Office of Basic Energy Sciences under Contract No. W-31-109-ENG-38.

The Advanced Photon Source (APS) is a third generation hard x-ray source serving a large user community. In order to characterize the high-brilliance beams, the APS diagnostics beamlines have been developed into a full photon diagnostics suite. We will describe the design and capabilities of the APS visible light imaging line, the bend magnet x-ray pinhole camera, and a unique diagnostics undulator beamline. Their primary functions are to support the APS user operations by providing information on beam sizes (20 - 100 micrometers), divergence (3 – 25 microradians), and bunch length (20 – 50 ps). Through the use of examples, we will show how these complementary imaging tools are used to visualize the electron dynamics and investigate beam instabilities. Special emphasis will be put on the use of undulator radiation, which is uniquely suitable for time-resolved imaging of electron beam with high spatial resolution, and for measurements of longitudinal beam properties such as beam energy spread and momentum compaction.

 
RPAE073 Generating Picosecond X-Ray Pulses with Beam Manipulation in Synchrotron Light Sources 3898
 
  • W. Guo, M. Borland, K.C. Harkay, V. Sajaev, B.X. Yang
    ANL, Argonne, Illinois
 
  Funding: Work supported by U. S. Department of Energy, Office of Basic Energy Sciences under Contract No. W-31-109-ENG-38.

The length of x-ray pulses generated by storage ring light sources is usually tens of picoseconds. For example, the value is 40 ps rms at the Advanced Photon Source (APS). Methods of x-ray pulse compression are of great interest at the APS. One possible method, per Zholents et al., is to tilt the electron bunch with deflecting rf cavities.* Alternately, we found that the electron bunch can develop a tilt after application of a vertical kick in the presence of nonzero chromaticity. After slicing, the x-ray pulse length is determined by the tilt angle and the vertical beam size. In principal, sub-picosecond pulses can be obtained at APS. To date we have observed 6 ps rms visible light pulses with a streak camera. Efforts are underway to attempt further compression of the x-ray pulse and to increase the brilliance. This method can be easily applied to any storage ring light sources to generate x-ray pulses up to two orders of magnitude shorter than the electron bunch length. In this paper, we will present the theory of bunch tilt, particularly the synchrobetatron coupling and decoherence beam dynamics, and the simulation and the experimental results will also be shown as verification.

*A. Zholents et al., NIM A 425, 385(1999).

 
TOAB009 Generation of Short X-Ray Pulses Using Crab Cavities at the Advanced Photon Source 668
 
  • K.C. Harkay, M. Borland, Y.-C. Chae, G. Decker, R.J. Dejus, L. Emery, W. Guo, D. Horan, K.-J. Kim, R. Kustom, D.M. Mills, S.V. Milton, G. Pile, V. Sajaev, S.D. Shastri, G.J. Waldschmidt, M. White, B.X. Yang
    ANL, Argonne, Illinois
  • A. Zholents
    LBNL, Berkeley, California
 
  Funding: Work supported by U.S. Department of Energy, Office of Basic Energy Sciences, under Contract No. W-31-109-ENG-38.

There is growing interest within the user community to utilize the pulsed nature of synchrotron radiation from storage ring sources. Conventional third-generation light sources can provide pulses on the order of 100 ps but typically cannot provide pulses of about 1 ps that some users now require to advance their research programs. However, it was recently proposed by A. Zholents et al. to use rf orbit deflection to generate subpicosecond X-ray pulses.* In this scheme, two crab cavities are used to deliver a longitudinally dependent vertical kick to the beam, thus exciting longitudinally correlated vertical motion of the electrons. This makes it possible to spatially separate the radiation coming from different longitudinal parts of the beam. An optical slit can then be used to slice out a short part of the radiation pulse, or an asymetrically cut crystal can be used to compress the radiation in time. In this paper, we present a feasibility study of this method applied to the Advanced Photon Source. We find that the pulse length can be decreased down to a few-picosecond range using superconducting crab cavities.

*A. Zholents et al., NIM A 425, 385 (1999).

 
RPAT065 A Wire Scanner Design for Electron Beam Profile Measurement in the Linac Coherent Light Source Undulator 3667
 
  • J.L. Bailey, T.W. Buffington, B.X. Yang
    ANL, Argonne, Illinois
 
  Funding: Work supported by U. S. Department of Energy, Office of Basic Energy Sciences under Contract No. W-31-109-ENG-38.

The Linac Coherent Light Source (LCLS), currently under design, requires beam diagnostic instruments between the magnets in the beam undulator section. Ten wire scanners are planned as one of the primary instruments to characterize electron beam properties. The development of these wire scanners presents several design challenges due to the need for high accuracy and resolution of the wire motion (3 microns tolerance, typical) and the high intensity of the beam (3400 A over an area of 30 micron rms radius). In this paper, we present the technical specification and design criteria for the scanners. We will also present the mechanical design of the UHV-compatible drive and its engineering analysis. Lastly, we present the wire card design and discuss associated thermal and mechanical issues originating from the highly intense x-ray and electron beams.

 
RPAT086 Dual-Sweep Streak Camera Measurements of the APS User Beams 4185
 
  • A.H. Lumpkin, B.X. Yang
    ANL, Argonne, Illinois
  • F. Sakamoto
    UTNL, Ibaraki
 
  Funding: Work supported by U.S. Department of Energy, Office of Basic Energy Sciences under Contract Number W-31-109-ENG-38.

The Advanced Photon Source (APS) is a hard x-ray user facility based on a 7-GeV storage ring (SR). To accommodate the requests of the diverse user community, the APS normally runs with a 24-singlets fill pattern, a hybrid fill with a singlet and eight septuplets, or a 324-singlet fill pattern. In all cases the total stored beam current is 100 mA, with the lattice providing a natural emittance of about 2.5 nm rad. The first two patterns are used with a top-up mode that involves injection of one pulse of ~2.5 nC every two minutes into the designated SR bucket. Since the partition of bunch current varies for the different fills as well as the loading of the rf cavities, dual-sweep streak camera measurements (Hamamatsu model C5680) have been performed to characterize the average and individual bunch lengths in the fill patterns and the phase slew that occurs within the patterns. The bunch lengths vary from 32 ps (σ) within the septuplet to 50 ps (σ) for the singlet in the hybrid fill. The phase slew is significant in the hybrid fill across the eight septuplets. Example streak images of each pattern will be presented and discussed.

 
RPAT087 Design of a High-Resolution Optical Transition Radiation Imager System for the Linac Coherent Light Source Undulator 4209
 
  • B.X. Yang, J.L. Bailey, S.J. Stein, D.R. Walters
    ANL, Argonne, Illinois
 
  Funding: Work supported by U.S. Department of Energy, Office of Basic Energy Sciences under Contract No. W-31-109-ENG-38.

The Linac Coherent Light Source (LCLS), a free-electron x-ray laser, is under design and construction. Its high intensity electron beam, 3400 A in peak current and 46 TW in peak power, is concentrated in a small area (30 micrometer rms in both horizontal and vertical directions) inside its undulator. Ten optical transition radiation (OTR) imagers are planned between the undulator segments for the characterization of the transverse profiles of the electron beam. In this paper, we present the performance requirements and technical requirements of the OTR imagers. We will discuss in detail the design of the OTR screen, the arrangement and modeling of the imaging optics, and the mechanical design and analysis of the compact camera module. Through a unique optical arrangement, this imager will achieve a fine resolution (12 micrometer rms or better) over the entire field of view (5 mm × 5 mm). The compact camera module will fit in the limited space available with remote focus adjustment. A digital camera will be used to read out the beam images in a programmable region (5 mm × 0.5 mm) at the full beam repetition rate (120 Hz), or over the entire field at a lower rate (15 Hz).

 
RPPT034 High-Resolution Undulator Measurements using Angle-Integrated Sponteneous Radiation 2342
 
  • B.X. Yang
    ANL, Argonne, Illinois
 
  Funding: Work supported by U. S. Department of Energy, Office of Basic Energy Sciences under Contract No. W-31-109-ENG-38.

The Linac Coherent Light Source (LCLS) is a fourth-generation light. Its proper operation requires a stringently controlled undulator field. The tolerance for the field parameter K is less than 1.5 × 10-4 for all thirty-three undulator segments totaling 112 meters. Even with the high quality of the LCLS electron beam (x- and y-emittance ~ 44 pm, energy spread ~0.03%), the fluctuation of the electron energy (~0.05%) presents a serious challenge to measurement techniques based on electron or x-ray beams. We propose a differential measurement technique that makes use of the angle-integrated spontaneous radiation intensities from two undulator segments. When the x-ray beams emitted from the two undulator segments are separated but allowed to pass through the same monochromator, the two beam intensities will change almost identically with the change of electron beam energy. As a result, the intensity difference becomes a very sensitive and reliable measure of the difference of the two undulators’ K-parameters. Results of comprehensive numerical simulations show that differences in the range of delta-K/K ~ 10-5 can be resolved, well within the tolerance for the LCLS operation.