A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Skaritka, J.

Paper Title Page
MPPT021 Magnetic Measurement System for the NSLS Superconducting Undulator Vertical Test Facility 1730
 
  • D.A. Harder, G. Rakowsky, J. Skaritka
    BNL, Upton, Long Island, New York
 
  One of the challenges of small-gap superconducting undulators is measurement of magnetic fields within the cold bore to characterize the device performance and to determine magnetic field errors for correction or shimming, as is done for room-temperature undulators. Both detailed field maps and integrated field measurements are required. This paper describes a 6-element, cryogenic Hall probe field mapper for the NSLS Superconducting Undulator Vertical Test Facility (VTF). The probe is designed to work in an aperture only 3 mm high. A pulsed-wire insert is also being developed, for visualization of the trajectory, for locating steering errors and for determining integrated multi-pole errors. The pulsed-wire insert will be interchangeable with the Hall probe mapper. The VTF and the magnetic measurement systems can accommodate undulators up to 0.4 m in length.

*J. Skaritka et al., MEDSI’04.

 
MPPT026 Insertion Device Upgrade Plans at the NSLS 1949
 
  • T. Tanabe, A. Blednykh, D.A. Harder, M. Lehecka, G. Rakowsky, J. Skaritka
    BNL, Upton, Long Island, New York
 
  This paper describes plans to upgrade insertion devices at the National Synchrotron Light Source (NSLS), Brookhaven National Laboratory, U.S.A. The aging wiggler (W80) at X25 is being replaced by a 1 m long in-vacuum mini-gap undulator (MGU-18) optimized for a dedicated macromolecular crystallography program. A new, 1/3 m long, in-vacuum undulator (MGU-13.5), will be installed between a pair of RF cavities at X9, and will serve a new beamline dedicated for small angle x-ray scattering (SAXS). Both MGU’s will have provision for cryocooling the NdFeB hybrid arrays to 150K to raise the field and K-value and to obtain better spectral coverage. Design issues of the devices and other considerations, especially magnetic measurement methods in low temperature will be discussed.  
TOAB003 First Results from the DUV-FEL Upgrade at BNL
 
  • X.J. Wang, J.B. Murphy, I.P. Pinayev, G. Rakowsky, J. Rose, T.V. Shaftan, B. Sheehy, J. Skaritka, Z. Wu, L.-H. Yu
    BNL, Upton, Long Island, New York
  • H. Loos
    SLAC, Menlo Park, California
 
  The DUV-FEL at BNL is the world’s only facility dedicated to laser-seeded FEL R&D and its applications. Tremendous progress was made in both HGHG FEL and its applications in the last couple years.*,** In response to the requests of many users to study chemical science at the facility, the DUV-FEL linac was upgraded from 200 to 300 MeV to enable the HGHG FEL to produce 100 uJ pulses of 100 nm light. This will establish the DUV FEL as a premier user facility for ultraviolet radiation and enable state-of-the-art gas phase photochemistry research. The upgraded facility will also make possible key R&D experiments such as higher harmonic HGHG (n>5) that would lay the groundwork for future X-ray FEL based on HGHG. The upgraded HGHG FEL will operate at the 4th harmonic with the seed laser at either 800 nm or 400nm. The increase of the electron beam energy will be accomplished by installing a 5th linac cavity and two 45 MW klystrons. New HGHG modulator and dispersion sections vacuum chambers will be manufactured to accommodate new matching optics and 8th harmonic HGHG. The initial results of the DUV-FEL upgrade and other FEL and accelerator physics R&D opportunities will be discussed.

*L.H. Yu et al., Phy. Rev. Lett. 91, 074801-1 (2003). **W. Li et al., Phy. Rev. Lett. 92, 083002-1(2004).

 
TOAB010 Research and Development of Variable Polarization Superconducting Undulator at the NSLS 734
 
  • S. Chouhan, D.A. Harder, G. Rakowsky, J. Skaritka, T. Tanabe
    BNL, Upton, Long Island, New York
 
  Funding: Office Of Science.

In this work a new concept for the construction of planar variable polarization superconductive insertion device is presented. The construction of the device with 8 mm gap and magnetic period of 26 mm is described compared with permanent magnet insertion device with the same gap & period length, as well as with previously published concepts. Advantage of this design include: (1) electrical tunability for both right and left circular and elliptical, as well as linear vertical or horizontal, (2) it requires no compensation of unwanted vertical field component and (3) used only simple windings of superconductive wire in an interlaced pattern. As a first step towards the construction of full-length device we propose to build & test a short prototype that will serve as a proof of the concept for versatile variable polarization superconductor magnet.

 
RPAE056 NSLS II: The Future of the NSLS 3345
 
  • J.B. Murphy, J. Bengtsson, R. Biscardi, A. Blednykh, G.L. Carr, W.R. Casey, S. Chouhan, S.B. Dierker, E. Haas, R. Heese, S. Hulbert, E.D. Johnson, C.C. Kao, S.L. Kramer, S. Krinsky, I.P. Pinayev, S. Pjerov, B. Podobedov, G. Rakowsky, J. Rose, T.V. Shaftan, B. Sheehy, J. Skaritka, N.A. Towne, J.-M. Wang, X.J. Wang, L.-H. Yu
    BNL, Upton, Long Island, New York
 
  Funding: Under Contract with the United States Department of Energy Contract Number DE-AC02-98CH10886

The National Synchrotron Light Source at BNL was the first dedicated light source facility and it has now operated for more than 20 years. During this time the user community has grown to more than 2400 users annually. To insure that this vibrant user community has access to the highest quality photon beams, the NSLS is pursuing the design of a new ultra-high brightness (~10E21) electron storage ring, tailored to the 0.3-20 KeV photon energy range. We present our preliminary design and review the critical accelerator physics design issues.