Mytrochenko, V.V.

Paper Title Page
TPPE051 The Optimization of the Electron Injector Resonance System Based on the Evanescent Oscillations 3170
 
  • S.A. Perezhogin, M.I. Ayzatskiy, K. Kramarenko, V.A. Kushnir, V.V. Mytrochenko, Z.V. Zhiglo
    NSC/KIPT, Kharkov
 
  The report presents the results of the bunching system optimization and electrons motion simulation in the compact S – band injector. The injector consists of the low-voltage diode electron gun and optimized bunching system based on the resonant system with the evanescent oscillations. The amplitude of RF electrical field is increased along the axis of the bunching system. The resonance system optimization allows to obtain electron bunches with the phase length less than 10° (for 70 % particles) at the injector exit.  
TPPE052 Characteristics of Electron Beam Produced by Magnetron Diode with a Secondary-Emission Cathode 3197
 
  • N.G. Reshetnyak, N. Aizatsky, A. Dovbnya, N.A. Dovbnya, V.V. Mytrochenko, V. Zakutin
    NSC/KIPT, Kharkov
 
  The beam parameters were investigated using an azimuth-sectionalized 8-channel Faraday cup and a 12-channel computer-aided measuring system. The magnetron diode had a cathode (40 mm in diameter) and a 15 mm anode-cathode gap. At a cathode voltage amplitude of 50 kV and a cathode magnetic field of ~1200 Oe, the diode generates a tubular electron beam with an outer diameter of 50 mm, an inner diameter of 44 mm, a beam current of ~50 A. The short time instability of the total beam current, and of the current from each of eight segments of the Faraday cup was estimated to be ~2 … 3%, and long time instability (3 hours) was 5…7 %. Azimuthal distribution of beam current was investigated versus the amplitude, distribution and direction of the magnetic field. At a cathode magnetic field of 1200 Oe, that falls off inhomogeneity in the vicinity of the Faraday cup down to ~800 Oe, the azimuthal beam current distribution has a ± (3 … 5)%. As the magnetic field strength increases up to ~1700 Oe in the region of beam emergence from the gun and the Faraday cup, the azimuthal inhomogeneity of the beam current increases up to ± (100 … 150)%.  
FPAE062 Beam Parameters of a Two-Sectional Electron Linac with the Injector Based on a Resonance System with Evanescent Oscillations 3567
 
  • V.V. Mytrochenko, M.I. Ayzatskiy, V.N. Boriskin, A. Dovbnya, I.V. Khodak, V.A. Kushnir, A. Opanasenko, S.A. Perezhogin, A.N. Savchenko, D.L. Stepin, V.I. Tatanov, Z.V. Zhiglo
    NSC/KIPT, Kharkov
 
  The S-band electron linac has been designed at NSC KIPT to cover an energy range from 30 to about of 100 MeV. The linac consists of a couple of the four-meter long piecewise homogeneous accelerating sections. Each section is supplied with RF power from a separate klystron. The peculiarity of the linac is using of the injector based on evanescent oscillations. The report presents both simulation results of self-consistent particle dynamics in the linac and results of measurement of beam parameters.