FOAA010 Full Characterization at Low Temperature of Piezoelectric Actuators Used for SRF Cavities Active Tuning 728
 
  • M. Fouaidy, S. Blivet, F. Chatelet, N. Hammoudi, G.M. Martinet, A. Olivier, H. Saugnac
    IPN, Orsay
 
  Funding: EU, CNRS-IN2P3.

In the frame of the CARE project activities, supported by EU, IPN Orsay participate to the development of a fast cold tuning system for SRF cavities operating at a temperature T=2 K. The study is aimed at full characterization of piezoelectric actuators at low temperature. A new experimental facility was developed for testing various prototypes piezoelectric actuators and successfully operated for T in the range 1.8 K-300 K. Different parameters were investigated as function of T: piezoelectric actuator displacement vs. applied voltage V, capacitance vs. T, dielectric and thermal properties vs. T and finally heating DT due to dielectric losses vs. modulating voltage Vmod and frequency. We observed a decrease of the Full Range Displacement (FRD or DX) of the actuator from ~40μm @ 300K down to 1.8μm-3μm @ 1.8K, depending on both material and fabrication process of the piezostacks. Besides, both material and fabrication process have a strong influence on the shape of the characteristics DX vs. T dependence. Moreover, the variations of losses tangent with T show a maximum at T in the range 30 K-120 K. Finally a dedicated facility located at CERI (Orléans, France) for radiation hardness tests of actuators with fast neutrons at T=4.2 K was developed and the first beam tests results are summarized.