A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Marone, A.

Paper Title Page
MPPT050 Test Results for LHC Insertion Region Dipole Magnets 3106
 
  • J.F. Muratore, M. Anerella, J.P. Cozzolino, G. Ganetis, A. Ghosh, R.C. Gupta, M. Harrison, A.K. Jain, A. Marone, S.R. Plate, J. Schmalzle, R.A. Thomas, P. Wanderer, E. Willen, K.-C. Wu
    BNL, Upton, Long Island, New York
 
  Funding: U.S. Department of Energy.

The Superconducting Magnet Division at Brookhaven National Laboratory (BNL) has made 20 insertion region dipoles for the Large Hadron Collider (LHC) at CERN. These 9.45 m-long, 8 cm aperture magnets have the same coil design as the arc dipoles now operating in the Relativistic Heavy Ion Collider (RHIC) at BNL and are of single aperture, twin aperture, and double cold mass configurations. They produce fields up to 3.8 T for operation at 7.56 TeV. Eighteen of these magnets have been tested at 4.5 K using either forced flow supercritical helium or liquid helium. The testing was especially important for the twin aperture models, which have the most challenging design. In these, the dipole fields in both apertures point in the same direction, unlike LHC arc dipoles. This paper reports on the results of these tests, including spontaneous quench performance, verification of quench protection heater operation, and magnetic field quality. Magnetic field measurements were done at 4.5K and at room temperature, and warm-cold correlations have been determined. Some dynamic measurements to study the effect of time decay and snapback at injection were also done, using a fast rotating coil.

 
MPPT046 Superconducting Helical Snake Magnet for the AGS 2935
 
  • E. Willen, M. Anerella, J. Escallier, G. Ganetis, A. Ghosh, R.C. Gupta, M. Harrison, A.K. Jain, A.U. Luccio, W.W. MacKay, A. Marone, J.F. Muratore, S.R. Plate, T. Roser, N. Tsoupas, P. Wanderer
    BNL, Upton, Long Island, New York
  • M. Okamura
    RIKEN, Saitama
 
  Funding: DOE

A superconducting helical magnet has been built for polarized proton acceleration in the Brookhaven AGS. This "partial Snake" magnet will help to reduce the loss of polarization of the beam due to machine resonances. It is a 3 T magnet some 1940 mm in magnetic length in which the dipole field rotates with a pitch of 0.2053 degrees/mm for 1154 mm in the center and a pitch of 0.3920 degrees/mm for 393 mm in each end. The coil cross-section is made of two slotted cylinders containing superconductor. In order to minimize residual offsets and deflections of the beam on its orbit through the Snake, a careful balancing of the coil parameters was necessary. In addition to the main helical coils, a solenoid winding was built on the cold bore tube inside the main coils to compensate for the axial component of the field that is experienced by the beam when it is off-axis in this helical magnet. Also, two dipole corrector magnets were placed on the same tube with the solenoid. A low heat leak cryostat was built so that the magnet can operate in the AGS cooled by several cryocoolers. The design, construction and performance of this unique magnet will be summarized.

 
TOAA009 Recent Test Results of the Fast-Pulsed 4 T COSO Dipole GSI 001 683
 
  • G. Moritz, J. Kaugerts
    GSI, Darmstadt
  • B. Auchmann, S. Russenschuck, R. de Maria
    CERN, Geneva
  • J. Escallier, G. Ganetis, A.K. Jain, A. Marone, J.F. Muratore, R.A. Thomas, P. Wanderer
    BNL, Upton, Long Island, New York
  • M. Wilson
    Oxford Instruments, Accelerator Technology Group, Oxford, Oxon
 
  For the FAIR-project at GSI a model dipole was built at BNL with the nominal field of 4 T and a nominal ramp rate of 1 T/s. The magnet design was similar to the RHIC dipole with some changes for loss reduction and better cooling. The magnet was already successfully tested in a vertical cryostat with good training behaviour. Cryogenic losses were measured and first results of field harmonics were published. However, for a better understanding of the cooling process quench currents at several ramp rates were investigated. Detailed measurements of the field harmonics at different ramp rates and at several cycles were performed. To separate the effects of the coil and the iron yoke the magnet was disassembled and tested as collared coil only. Recent test results will be presented.  
RPPP017 Compact Superconducting Final Focus Magnet Options for the ILC 1569
 
  • B. Parker, M. Anerella, J. Escallier, M. Harrison, P. He, A.K. Jain, A. Marone, K.-C. Wu
    BNL, Upton, Long Island, New York
  • T.W. Markiewicz, T.V.M. Maruyama, Y. Nosochkov, A. Seryi
    SLAC, Menlo Park, California
 
  Funding: Work supported by the U.S. Department of Energy under contracts DE-AC-02-98-CH10886 and DE-AC02-76SF00515.

We present a compact superconducting final focus (FF) magnet system for the ILC based on recent BNL direct wind technology developments. Direct wind gives an integrated coil prestress solution for small transverse size coils. With beam crossing angles more than 15 mr, disrupted beam from the IP passes outside the coil while incoming beam is strongly focused. A superconducting FF magnet is adjustable to accommodate collision energy changes, i.e. energy scans and low energy calibration runs. A separate extraction line permits optimization of post IP beam diagnostics. Direct wind construction allows adding separate coils of arbitrary multipolarity (such as sextupole coils for local chromaticity correction). In our simplest coil geometry extracted beam sees significant fringe field. Since the fringe field affects the extracted beam, we also study advanced configurations that give either dramatic fringe field reduction (especially critical for gamma-gamma colliders) or useful quadrupole focusing on the outgoing beam channel. We present prototype coil winding test results and discuss our progress toward an integrated FF solution that addresses important machine detector interface issues.