A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Mackenzie, G.H.

Paper Title Page
WPAE008 Redesign of a Low Energy Probe Head 1105
 
  • Y.-N. Rao, G.H. Mackenzie, T.C. Ries
    TRIUMF, Vancouver
 
  The present situation of the low energy probe L·102 in TRIUMF cyctron is that the thickness of finger 5 is uniform in the radial direction and its weight which amounts to ~447 g is affecting its re-circulating ball mechanism and causing it to fall below the median plane over its range of movement (13.890 to 161.515 inch). We first made simulations to determine the optimum thickness of the probe head vs the radial length so as to reduce its weight. And then, we compared the simulation results with experimental measurements made. Finally, we calculated the temperature rise caused by the beam power dumped on the probe, and figured out the maximum beam current that can be dumped on the finger.