A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Liu, G.

Paper Title Page
WPAT065 HLS RF System Improvement in NSRL Phase II Project 3653
 
  • K. Jin, Y. An, L. Feng, G. Huang, G. Liu, G. Wang, X. Zeng
    USTC/NSRL, Hefei, Anhui
 
  Hefei Light Source (HLS) is mainly composed of an 800 MeV electron storage ring and a 200 MeV Linac functioning as its injector. The RF system has been improved successfully for HLS storage-ring in NSRL Phase II Project. In this paper, the improvement of generator and power transmission system, the development of a new RF cavity and the perfection of RF controls are described in detail. The results and some analyses are presented.  
RPAE076 The Commission of Hefei Light Source After Reconstruction 3967
 
  • H. Xu, H. He, W. Li, G. Liu, L. Liu, S. Shang, B. Sun, L. Wang
    USTC/NSRL, Hefei, Anhui
 
  After the new four-kicker injection bump system was mounted, it was found that the magnetic field of four–kicker magnet through the same pulse current is different each other, the reason is which the width of pulse magnet fields is not same, so the four-kickers can not form completely local bump, and produce large global orbit distortion,and lead to beam loss. At last we found that the films of ceramic chambers were not plated evenly. The new rf system have two low level control circle circuits, which are the frequency and amplitude automatic adjustment systems. Because the energy of injection electron beam is 200MeV, and radiation damping is weak, so the gain of amplitude circuit was adjusted to the small value not to disturb beam.The beam load is large,and Robinson instability happen easily, so the small detune angle is preset. The Octupoles were inserted in ring for damping instability, and over compensated chromaticity was adjusted.Superconductor wiggler bring the variation of beta function, and the beam life time decreased from 8 hours to about 3 hours. By adjusting the beta functions close to situation ago, the beam lifetime was improved.  
FPAT072 The Status of HLS Control System 3862
 
  • G. Liu, X. Bao, C. Li, W. Li, J. Wang, Xie. Xie, K. Xuan
    USTC/NSRL, Hefei, Anhui
  • J. Li
    DU/FEL, Durham, North Carolina
 
  HLS (Hefei Light Source) at NSRL (National Synchrotron Radiation Lab) consists of three parts: 200Mev Linac, transport line and 800Mev storage ring. The control system was upgraded based on EPICS (Experimental Physics and Industrial Control system) from 1999 to 2004. This paper will cover the experience of using PC-based hardware under EPICS, data archiving, and some high level tools for physics and operation use.