A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Kramarenko, K.

Paper Title Page
TPPE051 The Optimization of the Electron Injector Resonance System Based on the Evanescent Oscillations 3170
 
  • S.A. Perezhogin, M.I. Ayzatskiy, K. Kramarenko, V.A. Kushnir, V.V. Mytrochenko, Z.V. Zhiglo
    NSC/KIPT, Kharkov
 
  The report presents the results of the bunching system optimization and electrons motion simulation in the compact S – band injector. The injector consists of the low-voltage diode electron gun and optimized bunching system based on the resonant system with the evanescent oscillations. The amplitude of RF electrical field is increased along the axis of the bunching system. The resonance system optimization allows to obtain electron bunches with the phase length less than 10° (for 70 % particles) at the injector exit.