Paper |
Title |
Page |
MPPT075 |
Analysis and Design of Backing Beam for Multipole Wiggler (MPW14) at PLS
|
3940 |
|
- H.-G. Lee, C.W. Chung, H.S. Han, Y.G. Jung, D.E. Kim, W.W. Lee, K.-H. Park, H.S. Suh
PAL, Pohang, Kyungbuk
|
|
|
Pohang Accelerator Laboratory (PAL) had developed and installed a Multipole Wiggler (MPW14) to utilize high energy synchrotron radiation at Pohang Light Source (PLS). The MPW14 is a hybrid type device with period of 14 cm, minimum gap of 14 mm, maximum flux density of 2.02 Tesla and total magnetic structure length of 2056 mm. The support locations and structure of an insertion device are optimized to achieve a minimum deflection due to the magnetic loads. A Finite Element Analysis (FEA) is performed to find out the amount of maximum deflection and optimal support positions on the backing beam, the support and drive structures of the MPW14 under expected magnetic load of 14 tons. To reduce the deflection effect further, two springs are designed and installed to compensate the gap dependent magnetic loads. The optimized deflection is estimated to be about 20.6 ? while the deflection before optimization is 238 ?.
|
|
WPAE016 |
Development of a Precision Amplifier for the Detector
|
1514 |
|
- K.-H. Park, C.W. Chung, S.-M. Hong, S.-H. Jeong, Y.G. Jung, D.E. Kim, H.-S. Lee, W.W. Lee
PAL, Pohang, Kyungbuk
- B.-K. Kang
POSTECH, Pohang, Kyungbuk
|
|
|
A high gain trans-resistance amplfier has been developed for measuring the intensity of synchrotron radiation at Pohang Light Source(PLS). This amplifier built with discrete elements and operational amplifiers.It had the capability of measuring range from 1pA to 1 uA with good linearity. A microprocessor was also installed to interface the amplifier with the computer, and controlled the other sub-circuits. The various characteristics of amplifier such as linearity, sensitivity,stability, etc. have been investigated, and its experimental results carried out at the beam line are presented in this paper.
|
|