WPAP016 High Brightness Electron Gun for X-Ray Source 1488
 
  • S. Ohsawa, M. Ikeda, T. Sugimura, M. Tawada
    KEK, Ibaraki
  • Y. Hozumi
    GUAS/AS, Ibaraki
  • K. Kanno
    AET Japan, Inc., Kawasaki-City
 
  A new electron-gun system is under development in order to increase X-ray from a rotating target. In commercial X-ray sources electron beams usually hit targets at the outer part. Owing to deformation by centrifugal force, there has been a limit on electron beam intensities. In order to overcome this difficulty, we adopted a new injection system which strikes inside of a ring-shape projection on a rotating target. It has an advantage in that heated-up points have supports back side against centrifugal force. This merit allows us to raise electron beam to give stronger X-rays.