A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Huang, Z.

Paper Title Page
TOAC005 Coherent Synchrotron Radiation as a Diagnostic Tool for the LCLS Longitudinal Feedback System 428
 
  • J. Wu, P. Emma, Z. Huang
    SLAC, Menlo Park, California
 
  Funding: Work is supported by the US Department of Energy under contract DE-AC02-76SF00515.

The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, a longitudinal feedback system is required together with other diagnostics. In this paper, we study the possibility of using Coherent Synchrotron Radiation (CSR) from the chicane as the diagnostic tool for bunch length feedback. Calculations show that CSR is a good candidate, even for the non-Gaussian, double-horn longitudinal charge distribution. We further check the feasibility for low and high charge options, and also the possibility for detecting the microbunching.

 
TPAT062 Uncorrelated Energy Spread and Longitudinal Emittance for a Photoinjector Beam 3570
 
  • Z. Huang, D. Dowell, P. Emma, C. Limborg-Deprey, G.V. Stupakov, J. Wu
    SLAC, Menlo Park, California
 
  Longitudinal phase space properties of a photoinjector beam are important in many areas of high-brightness beam applications such as bunch compression, transverse-to-longitudinal emittance exchange, and high-gain free-electron lasers. In this paper, we discuss both the rf and the space charge contributions to the uncorrelated energy spread of the beam generated from a laser-driven rf gun. We compare analytical expressions for the uncorrelated energy spread and the longitudinal emittance with numerical simulations and recent experimental results.  
TOAB004 An Optimized Low-Charge Configuration of the Linac Coherent Light Source 344
 
  • P. Emma, Z. Huang, C. Limborg-Deprey, J. Wu
    SLAC, Menlo Park, California
  • W.M. Fawley, M.S. Zolotorev
    LBNL, Berkeley, California
  • S. Reiche
    UCLA, Los Angeles, California
 
  Funding: Work supported by U.S. Department of Energy contract DE-AC02-76SF00515.

The Linac Coherent Light Source (LCLS) is an x-ray free-electron laser (FEL) project based on the SLAC linac. The nominal parameter set is founded on a 1-nC bunch charge and normalized emittance of about 1 micron. The most challenging issues, such as emittance generation, wakefields, and coherent synchrotron radiation (CSR), are associated with the high bunch charge. In the LCLS in particular, with its strong linac wakefields, the bunch compression process produces sharp temporal horns at the head and tail of the bunch with degraded local emittance, effectively wasting much of the charge. The sharp horns intensify CSR in the bends and further drive a strong resistive-wall wakefield in the long FEL undulator. Although these issues are not insurmountable, they suggest a lower bunch charge may be more suitable. This study uses a 0.2-nC bunch charge and 0.85-micron emittance with only 30 A of peak current in the injector, producing the same FEL saturation length. The resulting performance is more stable, has negligible resistive-wall wakefield, greatly reduced CSR effects, and no transverse wakefield emittance dilution in the linac, with no change to the baseline engineering design.

 
RPPT028 Free Electron Lasers with Slowly Varying Beam and Undulator Parameters 2059
 
  • Z. Huang, G.V. Stupakov
    SLAC, Menlo Park, California
 
  The performance of a free electron lasers (FEL) is affected when the electron beam energy varies alone the undulator as would be caused by vacuum pipe wakefields and/or when the undulator strength parameter is tapered in the small signal regime until FEL saturation. In this paper, we present a self-consistent theory of FELs with slowly-varying beam and undulator parameters. A general method is developed to apply the WKB approximation to the beam-radiation system by employing the adjoint eigenvector that is orthogonal to the eigenfunctions of the coupled Maxwell-Vlasov equations. This method may be useful for other slowly varying processes in beam dynamics.  
RPPT035 Optimization of the LCLS X-Rray FEL Output Performance in the Presence of Strong Undulator Wakefields 2396
 
  • S. Reiche
    UCLA, Los Angeles, California
  • K.L.F. Bane, P. Emma, Z. Huang, H.-D. Nuhn, G.V. Stupakov
    SLAC, Menlo Park, California
  • W.M. Fawley
    LBNL, Berkeley, California
 
  Funding: The work was supported by the DOE Contract No. DE-AC02-76SF00515.

The Linac Coherent Light Source (LCLS) Free-Electron Laser will operate in the wavelength range of 1.5 to 15 Angstroms. Energy loss due to wakefields within the long undulator can degrade the FEL process by detuning the resonant FEL frequency. The wakefields arise from the vacuum chamber wall resistivity, its surface roughness, and abrupt changes in its aperture. For LCLS parameters, the resistive component is the most critical and depends upon the chamber material (e.g. Cu) and its radius. To study the expected performance in the presence of these wakefields, we make a series of "start-to-end" simulations with tracking codes PARMELA and ELEGANT and time-dependent FEL simulation codes Genesis 1.3 and Ginger. We discuss the impact of the wakefield on output energy, spectral bandwidth, and temporal envelope of the output FEL pulse, as well as the benefits of a partial compensation obtained with a slight z dependent taper in the undulator field. We compare these results to those obtained by decreasing the bunch charge or increasing the vacuum chamber radius. We also compare our results to those predicted in concurrent analytical work.

 
RPPT040 Weak FEL Gain Detection with a Modulated Laser-Based Beam Heater 2636
 
  • P. Emma, Z. Huang, J. Wu
    SLAC, Menlo Park, California
 
  For an x-ray free-electron laser (FEL) such as the LCLS, the FEL gain signal is accompanied by spontaneous radiation with a significant power level. Detecting the weak FEL gain among the large spontaneous background in the early stage of the exponential growth or for a low quality electron beam is important in commissioning the FEL. In this paper, we describe a simple "lock-in" method of weak FEL gain detection by slowly modulating the laser power of a designated beam heater that controls the local energy spread of the electron beam. We present numerical modeling that shows the effectiveness of this method and discuss its implementation in the LCLS.