WPAE018 Performance Tests of Survey Instruments Used in Radiation Fields Around High-Energy Accelerators 1595
 
  • S. Mayer, D. Forkel-Wirth, M. Fuerstner, H.G. Menzel, S. Roesler, C. Theis, H. Vincke
    CERN, Geneva
 
  Measurements of ambient dose equivalent in stray radiation fields behind the shielding of high-energy accelerators are a challenging task. Several radiation components (photons, neutrons, charged particles), spanning a wide range of energies, contribute to the total dose equivalent. In routine-measurements, the total dose equivalent is obtained by the combination of several radiation detectors. Ionisation chambers, which are sensitive to all radiation components, are employed together with so-called REM counters, which are responding mainly to neutrons. The total dose equivalent is correctly assessed provided that the response is interpreted carefully by using appropriate corrections and calibration factors. For this reason measurements were carried out in a high-energy reference field at CERN, which allows one to study the response of the different detectors in a mixed radiation field under controlled conditions. In addition, the field was simulated by Monte Carlo simulations. The outcome of these studies serves on one hand as a basis for quality assurance and improves on the other hand the knowledge of the instrument’s response for future applications at the LHC.  
WPAE050 First Calibrations of Alanine and Radio-Photo-Luminescence Dosemeters to a Hadronic Radiation Environment 3097
 
  • M. Fuerstner, I. Brunner, D. Forkel-Wirth, S. Mayer, H.G. Menzel, H. Vincke
    CERN, Geneva
  • I. Floret
    Ecole d'ingénieurs de Genève, Genève
 
  Alanine and Radio-Photo-Luminescence (RPL) dosimeters are used to monitor radiation doses occurring inside the tunnels of all CERN accelerators including the Large Hadron Collider (LHC). They are placed close to radiation sensitive machine components like cables or insulation of magnet coils to predict their remaining lifetime. The dosimeters are exposed to mixed high-energy radiation fields. However, up to now both dosimeter types are calibrated to 60Co-photons only. In order to study the response of RPL and alanine dosimeters to mixed particle fields like those occurring at CERN’s accelerators, an irradiation campaign at the CERN-EC High-Energy Reference field Facility (CERF-field) was performed. Moreover, the dosimeters were first time calibrated to a proton radiation field of a constant momentum of 24 GeV/c. In addition to the experiment FLUKA Monte Carlo simulations were carried out, which provide information concerning the energy deposition and the radiation field at the dosimeter locations.