A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Davis, G.K.

Paper Title Page
TPPT073 Testing of the New Tuner Design for the CEBAF 12 GeV Upgrade SRF Cavities 3910
 
  • E. Daly, G.K. Davis, W.R. Hicks
    Jefferson Lab, Newport News, Virginia
 
  Funding: This manuscript has been authorized by SURA, Inc. under Contract No. DE-AC05-84ER-40150 with the U.S. Department of Energy.

The new tuner design for the 12 GeV Upgrade SRF cavities consists of a coarse mechanical tuner and a fine piezoelectric tuner. The mechanism provides a 30:1 mechanical advantage, is pre-loaded at room temperature and tunes the cavities in tension only. All of the components are located in the insulating vacuum space and attached to the helium vessel, including the motor, harmonic drive and piezoelectric actuators. The requirements and detailed design are presented. Measurements of range and resolution of the coarse tuner are presented and discussed.

 
TPPT083 RF Conditioning and Testing of Fundamental Power Couplers for SNS Superconducting Cavity Production 4132
 
  • M. Stirbet, G.K. Davis, M. A. Drury, C. Grenoble, J. Henry, G. Myneni, T. Powers, K. Wilson, M. Wiseman
    Jefferson Lab, Newport News, Virginia
  • I.E. Campisi, Y.W. Kang, D. Stout
    ORNL, Oak Ridge, Tennessee
 
  Funding: This work was supported by U.S. DOE contract DE-AC0500R22725.

The Spallation Neutron Source (SNS) makes use of 33 medium beta (0.61) and 48 high beta (0.81) superconducting cavities. Each cavity is equipped with a fundamental power coupler, which should withstand the full klystron power of 550 kW in full reflection for the duration of an RF pulse of 1.3 msec at 60 Hz repetition rate. Before assembly to a superconducting cavity, the vacuum components of the coupler are submitted to acceptance procedures consisting of preliminary quality assessments, cleaning and clean room assembly, vacuum leak checks and baking under vacuum, followed by conditioning and RF high power testing. Similar acceptance procedures (except clean room assembly and baking) were applied for the airside components of the coupler. All 81 fundamental power couplers for SNS superconducting cavity production have been RF power tested at JLAB Newport News and, beginning in April 2004 at SNS Oak Ridge. This paper gives details of coupler processing and RF high power-assessed performances.

 
WPAT059 High Power RF Test Facility at the SNS 3450
 
  • Y.W. Kang, D.E. Anderson, I.E. Campisi, M. Champion, M.T. Crofford, R.E. Fuja, P.A. Gurd, S. Hasan, K.-U. Kasemir, M.P. McCarthy, D. Stout, J.Y. Tang, A.V. Vassioutchenko, M. Wezensky
    ORNL, Oak Ridge, Tennessee
  • G.K. Davis, M. A. Drury, T. Powers, M. Stirbet
    Jefferson Lab, Newport News, Virginia
 
  RF Test Facility has been completed in the SNS project at ORNL to support test and conditioning operation of RF subsystems and components. The system consists of two transmitters for two klystrons powered by a common high voltage pulsed converter modulator that can provide power to two independent RF systems. The waveguides are configured with WR2100 and WR1150 sizes for presently used frequencies: 402.5 MHz and 805 MHz. Both 402.5 MHz and 805 MHz systems have circulator protected klystrons that can be powered by the modulator capable of delivering 11 MW peak and 1 MW average power. The facility has been equipped with computer control for various RF processing and complete dual frequency operation. More than forty 805 MHz fundamental power couplers for the SNS superconducting linac (SCL) cavitites have been RF conditioned in this facility. The facility provides more than 1000 ft2 floor area for various test setups. The facility also has a shielded cave area that can support high power tests of normal conducting and superconducting accelerating cavities and components.

SNS is managed by UT-Battelle, LLC, under contract DE-AC05-00OR22725 for the U.S. Department of Energy. SNS is a partnership of six national laboratories: Argonne, Brookhaven, Jefferson, Lawrence Berkeley, Los Alamos, and Oak Ridge.

 
RPPE060 Overview of SNS Cryomodule Performance 3496
 
  • M. A. Drury, E. Daly, G.K. Davis, J.R. Delayen, C. Grenoble, W.R. Hicks, K. King, T. Plawski, T. Powers, J.P. Preble, H. Wang, M. Wiseman
    Jefferson Lab, Newport News, Virginia
 
  Funding: Supported by U.S. DOE Contract Nos. DE-AC05-84ER40150.

Thomas Jefferson National Accelerating Facility (Jefferson Lab) has completed production of 24 Superconducting Radio Frequency (SRF) cryomodules for the Spallation Neutron Source (SNS) superconducting linac. This includes one medium-beta (0.61) prototype, eleven medium-beta and twelve high-beta (0.81) production cryomodules. Ten medium-beta cryomodules as well as two high beta cryomodules have undergone complete operational performance testing in the Cryomodule Test Facility at Jefferson Lab. The set of tests includes measurements of maximum gradient, unloaded Q (Q0), microphonics, and response to Lorentz forces. The Qext’s of the various couplers are measured and the behavior of the higher order mode couplers is examined. The mechanical and piezo tuners are also characterized. The results of these performance tests will be discussed in this paper.

 
RPPE068 A Magnetostrictive Tuning System for Particle Accelerators 3762
 
  • C.-Y. Tai, J. Cormier, W. J. Espinola, Z. Han, C.H. Joshi, A. Mavanur, L.M. Racz
    Energen, Inc., Lowell, Massachusetts
  • E. Daly, G.K. Davis
    Jefferson Lab, Newport News, Virginia
  • K.W. Shepard
    ANL, Argonne, Illinois
 
  Funding: This work is supported by DOE SBIR Program DE-FG02-03ER83648.

Energen, Inc. has designed, built, and demonstrated several fast and slow tuners based on its magnetostrictive actuators and stepper motor. These tuners are designed for Superconducting Radio Frequency (SRF) cavities, which are important structures in particle accelerators that support a wide spectrum of disciplines, including nuclear and high-energy physics and free electron lasers (FEL). In the past two years, Energen’s work has focused on magnetostrictive fast tuners for microphonics and Lorentz detuning compensation on elliptical-cell and spoke-loaded cavities, including the capability for real-time closed-loop control. These tuners were custom designed to meet specific requirements, which included a few to 100 micron stroke range, hundreds to kilohertz operation frequency, and cryogenic temperature operation in vacuum or liquid helium. These tuners have been tested in house and at different laboratories, such as DESY, Argonne National Lab, and Jefferson Lab. Some recent results are presented in this paper.