Paper | Title | Page |
---|---|---|
MOPOB58 | Eddy Current Calculations for a 1.495 GHz Injection-Locked Magnetron | 198 |
|
||
An injection-locked amplitude modulated magnetron is being developed as a reliable, efficient RF source that could replace klystrons used in particle accelerators. The magnetron amplitude is modulated using a trim magnetic coil to alter the magnetic field in conjunction with the anode voltage to suppress the emittance growth due to microphonics and changing beam loads. The rate for microphonic noise can have frequencies in the range 10-50 Hz. This is competitive to the inductive decay time of the trim coil. Eddy currents will be induced in the copper anode of the magnetron that will buck the field from the trim coil in the interaction region. This paper will describe the magnetic circuit of the proposed magnetron as well as the calculation and handling of the Eddy currents on the magnetic field. | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-NAPAC2016-MOPOB58 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
FRA1CO05 | Progress of Gas-Filled Multi-RF-Cavity Beam Profile Monitor for Intense Neutrino Beams | 1275 |
|
||
Funding: Work supported by Fermilab Research Alliance, LLC under Contract No. DE-AC02-07CH11359 and DOE STTR Grant, No. DE-SC0013795. A novel pressurized gas-filled multi-RF-cavity beam profile monitor has been studied that is simple and robust in high-radiation environments. Charged particles passing through each RF-cavity in the monitor produce intensity-dependent ionized plasma, which changes the gas permittivity. The sensitivity to beam intensity is adjustable using gas pressure and RF gradient. The performance of the gas-filled beam profile monitor has been numerically simulated to evaluate the sensitivity of permittivity measurements. The result indicates that the RF resonator will be useful to measure the beam profile with a charged beam intensity range from 106 to 1013 protons/bunch. The range covers the expected beam intensities in NuMI and LBNF. The demonstration of the monitor with intense proton beams are taken place at Fermilab to validate the simulation result. The result will be given in this presentation. |
||
![]() |
Slides FRA1CO05 [3.750 MB] | |
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-NAPAC2016-FRA1CO05 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |