Author: Thiel, A.
Paper Title Page
TUOPMA04 Apple II Insertion Devices Made at MAXIV 6
 
  • A. Thiel, M. Ebbeni, H. Tarawneh
    MAX IV Laboratory, Lund University, Lund, Sweden
 
  At present five Apple II insertion devices were made and installed at MAX IV, three of them in the 1.5GeV-ring, and two in the 3GeV-ring. The assembly of the last one of a total number of six Apple II undulators made at MAX IV is currently going on. The undulators have period lengths of 48mm (two devices), 53mm, 58mm, 84mm and 95.2mm. The operational gap range of the 3GeV devices is between 11mm and 150mm, the range of the 1.5GeV devices is 14mm to 150mm. Structural analysis was applied to assure a minimum deflection of the main frame and the magnet array girders. The main frame is made of nodular cast iron, while the girders are made of aluminium alloy. In order to optimize the magnetic tuning the position of the magnet keepers can be adjusted by wedges. The undulators were fiducialized before the installation in the ring tunnel and were aligned in the straight section using their magnetic centre as reference. All MAX IV made undulators have three feet with vertical adjustment and separate horizontal adjusters. This paper describes the design, assembly, shimming and installation of the MAX IV Apple II devices in more detail.  
slides icon Slides TUOPMA04 [12.328 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUOPMA04  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)