Author: Pinty, V.
Paper Title Page
THPH32 Dual Beam Visualizer - Intensity Monitor for Lucia Beamline at SOLEIL Synchrotron 403
 
  • C. Menneglier, D.K. Desjardins, V. Pinty, D. Roy, D. Vantelon
    SOLEIL, Gif-sur-Yvette, France
 
  LUCIA is a micro-focused beamline (0.8 - 8 keV) dedicated to X-ray fluorescence and X-ray absorption spectroscopy at SOLEIL Synchrotron.* With its recent optical upgrade and photons flux increase, the three pink-beam diagnostics of the beamline have been upgraded to support a beam reaching 1013ph/s and 20 W/mm². This paper presents the thermomechanical study and the realization of new devices adapted to the current constraints of use, making possible to both visualize the shape of the pink beam and to measure its intensity simultaneously in the same compact device. The beam is visualized by a piece of Al2O3 - Cr ceramic, soldered to a copper heat sink, whose fluorescence image is visible in visible light with a suitable camera and optical system. The measurement of the photonic intensity is made by a polarized CVD diamond used as a photosensitive element, the current reading is made by a suitable low current amplifier. The design of this dual beam visualizer and intensity monitor, made by the SOLEIL detectors group with thermomechanical studies done by the Mechanical Design Office, will be presented in details. In-lab measurements will be also presented.
* D. Vantelon et al., The LUCIA beamline at SOLEIL, Journal of Synchrotron Radiation, vol 23 (part 2), pp 635-640, March 2016. doi:10.1107/S1600577516000746
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-THPH32  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPH37 MAGSTAT V3: An In-Vacuum Variable-Gap Quadrupole with Rotary Permanent Magnets 412
 
  • V. Pinty, N. Jaouen, F. Marteau, H. Popescu, P. Prout
    SOLEIL, Gif-sur-Yvette, France
 
  MAGSTAT is a quadrupole designed to magnetize samples with a variable magnetic field in flow density and in directions. Four rotary permanent magnets allow the user to specify a direction for the field and changing in situ the gap between the poles drives the field intensity. The first prototype was realized in 2016 on the SEXTANTS beamline in the framework of SOLEIL-MAXIV collaboration; a second version has been manufactured for MAXIV SoftImax beamline. This third version shows a significant evolution of the mechanical design, guaranteeing a much better stiffness in high field configurations. Samples up to Ø74mm can be placed in this quadrupole, and the tiny ones which may fit in a Ø10mm circle or smaller, can be magnetized with a 1T local field. The angle of each magnet is driven by a dedicated stepper motors with a big reduction ratio. The total gap is ensured by a single motor, and its motion is symmetrically transferred to the magnets through an Archimedean spiral. The first prototype is installed at COMET endstation dedicated to the coherent scattering of soft X-ray in transmission for imaging magnetic materials via the Fourier Transform Holography or ptychography techniques.  
poster icon Poster THPH37 [57.424 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-THPH37  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)