Author: Li, Z. L.
Paper Title Page
WEPH09 Vibrational Stability of a Cryocooled Double Crystal Monochromator at SSRF 220
 
  • Y. Fan, H.L. Qin
    SSRF, Shanghai, People's Republic of China
  • Z. L. Li, F. Tao, W. Zhu
    SINAP, Shanghai, People's Republic of China
 
  There is an increasingly critical demand on the angular stability of double crystal monochromator (DCM). This work focuses on a method to measure angular vibration directly at the DCM crystals using a dual-frequency interferometer. This method was applied to the off-line test of a newly developed cryocooled DCM at Shanghai Syn-chrotron Radiation Facility (SSRF), which can obtain a resolution of 8 nrad. The DCM was then tested on the X-ray Test Line. Both off-line and on-line results were referenced for DCM structure optimizations. In this paper, the DCM angular stability measuring method is presented, and detailed information of the results are shown.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-WEPH09  