Author: Labat, M.
Paper Title Page
TUPH11 Retractable Absorber (Mask) and White Beam Imager Diagnostic for Canted Straight Section 45
 
  • J. Da Silva Castro, N. Béchu, C. Herbeaux, N. Hubert, N. Jobert, M. Labat, F. Lepage, A. Mary, K.T. Tavakoli
    SOLEIL, Gif-sur-Yvette, France
 
  At the SOLEIL synchrotron, as in other accelerators, two canted sources can coexist on the same straight section for space and economic reasons. For its two long beamlines (ANATOMIX source upstream and NANOSCOPIUM source downstream) SOLEIL has made the choice to equip one of his long straight section with two canted insertion devices capable to operate simultaneously. That implies to take into account the degradation risk management of equipment, due to radiation. As the beam power deposition from the upstream undulator can seriously degrade the downstream one, or even other equipment. To handle these risks, Soleil first designed and installed in 2016 a retractable vertical absorber between both insertions to protect the downstream source from the upstream one. In 2017, Soleil then designed and installed a white beam imager, redundant an existing photon beam monitor (XBPM), to verify the correct positioning / alignment of equipment and beams relative to each other. For the vertical absorber as for the white beam imager Soleil had to meet some interesting technological and manufacturing aspects that we propose to present in a poster.  
poster icon Poster TUPH11 [3.744 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH11  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)