THPH24 Front End Designs for the Advanced Photon Source Multi-bend Achromats Upgrade 388
 
  • Y. Jaski, M. Abliz, J.S. Downey, S.H. Lee, J. Mulvey, S.M. Oprondek, M. Ramanathan, F. Westferro, B.X. Yang
    ANL, Argonne, Illinois, USA
 
  Funding: Work supported by the U.S. Department of Energy, Office of Science, under Contract No. DE-AC02-06CH11357
The Advanced Photon Source (APS) upgrade from double-bend achromats (DBA) to multi-bend achromats (MBA) lattice is underway. This upgrade will change the storage ring energy from 7 GeV to 6 GeV and beam current from 100 mA to 200 mA. All front ends must be upgraded to fulfill the following requirements: 1) Include a clearing magnet in all front ends to deflect and dump any electrons in case the electrons escape from the storage ring during swap-out injection with the safety shutters open, 2) Incorporate the next generation x-ray beam position monitors (XBPMs) into the front ends to meet the new stringent beam stability requirements, 3) For insertion device (ID) front ends, handle the high heat load from two undulators in either inline or canted configuration. The upgraded APS ID front ends will only have two types: High Heat Load Front End (HHLFE) for single beam and Canted Undulator Front End (CUFE) for canted beam. This paper presents the final design of the HHLFE and preliminary design of the CUFE.
 
poster icon Poster THPH24 [1.279 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-THPH24  