Author: Nowak, M.P.
Paper Title Page
MOPE07 Ground Motions Measurements for Synchrotron 15
 
  • D.T. Ziemianski
    CUT, Kraków, Poland
  • M.P. Nowak
    Solaris, Kraków, Poland
 
  For more than two decades, ground vibration measurements were made by different teams for feasibility studies of linear accelerators. Recent measurements were performed in the SPS tunnel and at different CERN sites on the surface. The devices to measure vibrations of magnitude ranging in nanometres, the analysis techniques and the results are critically discussed and compared with the former measurements. The implication of the measured integrated R.M.S. displacements for the Crab cavities cavern is mentioned. The equipment used in this study consists of 2 state-of-the-art Guralp broadband triaxial seismometers. Models CMG-T60-0004 performed measurements in three directions V, N/S and E/W. The first analysis was to evaluate the power spectral density for each direction of sensors and event. The power spectral density is calculated from the auto power spectrum. The power spectral density shows a typical curve for the geophones with theμseismic peak between 0.2 and 0.4 [Hz]. It is import ant to point that ground vibrations should not be ignored in planning accelerator facility. Actually it is one of the limiting factor in the optimization of future accelerators.  
poster icon Poster MOPE07 [4.968 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2016-MOPE07  
About • paper received ※ 09 September 2016       paper accepted ※ 15 September 2016       issue date ※ 22 June 2017  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPE10 Dynamic Analysis and Measurement of Ground Motion for the Solaris - National Synchrotron Radiation Centre in Cracow 24
 
  • D.T. Ziemianski
    CUT, Kraków, Poland
  • M.P. Nowak
    Solaris National Synchrotron Radiation Centre, Jagiellonian University, Kraków, Poland
 
  The paper presents the results of the ground motion measurements and dynamic analysis performed in the Polish synchrotron radiation facility Solaris. The analysis has been carried out within the framework of the installation experimental lines inside Solaris building and accelerator tunnel. The equipment used in this study consists of 4 seismic, high sensitivity, ceramic flexural ICP accelerometer Models 393B31 (PCB), which performed measurements in one vertical directions. The first analysis was to evaluate the power spectral density for each sensors and event. The power spectral density is calculated from the auto power spectrum. The power spectral density shows a typical curve with theμseismic peak between 0.2 and 0.4 Hz. It is important to point that ground vibrations should not be ignored in planning accelerator facility. All over the measurement, the RMS integrated level in the vertical direction at 1 Hz were calculated and presented in paper.  
poster icon Poster MOPE10 [2.916 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2016-MOPE10  
About • paper received ※ 09 September 2016       paper accepted ※ 23 September 2016       issue date ※ 22 June 2017  