Author: Kitegi, C.A.    [Kitégi, C.A.]
Paper Title Page
TUPE04 Coherent Soft X-Ray EPU Vacuum Chamber Thermal Analysis for Synchrotron Radiation Protection 159
 
  • H.C. Fernandes, P.L. Cappadoro, D.A. Harder, D.A. Hidas, C.A. Kitégi, M. Musardo, J. Rank, T. Tanabe
    BNL, Upton, Long Island, New York, USA
 
  Funding: Department of Energy
The purpose of this study was to determine the effect of beam mis-steering, on the temperature of the vacuum chamber. The chamber used for this study was for the Coherent Soft X-Ray (CSX) Elliptically Polarizing Undulator (EPU). Finite Element Analysis was conducted on the vacuum chamber to determine the temperature distribution on the chamber for set values of beam mis-steer, for NSLS-II. These results were then compared with on-site temperature measurements taken using RTD¿s, as well as thermal sensitive cameras. The accuracy of these results was analyzed and further FEA studies were proposed for steeper beam mis-steers and beam offsets.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2016-TUPE04  
About • paper received ※ 09 September 2016       paper accepted ※ 20 September 2016       issue date ※ 22 June 2017  