Author: Chen, S.Y.
Paper Title Page
TUPE19 Application of a NEG Coated Chamber at the Canadian Light Source 205
 
  • S.Y. Chen, D. Bertwistle, K. Kei, C. Murray, T.M. Pedersen
    CLS, Saskatoon, Saskatchewan, Canada
 
  In the Fall of 2015 a 4800 mm long NEG coated chamber was installed in the Canadian Light Source in cell 9 straight section. The chamber will occupy to majority of the straight length. The chambers vacuum has been monitored for +1 year and no obvious issues has been found. The chamber body is 10 mm thick and the aperture is an ellipse with a 8 mm height and a 65 mm width. A design feature of the chamber is a lack of support in-between the ends of the chamber. The lack of support space is due to the double elliptically polarizing undulator (54 mm, and 180 mm period). This proceeding details the following: a.The structure design and Finite Element Analysis for the deflection and strength; b.Heat loads and cooling calculation; c.Supports design; d.Deflection and correction with the supports; e.Current strips installation f.Activation;  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2016-TUPE19  
About • paper received ※ 15 September 2016       paper accepted ※ 23 September 2016       issue date ※ 22 June 2017  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)