Paper |
Title |
Page |
WECA03 |
Experience With the Commissioning of the U15-Undulator for SwissFEL-Aramis Beamline and New Developments for the Athos Beamline |
283 |
|
- P. Boehler, M. Brügger, M. Calvi, H. Jöhri, A. Keller, M. Locher, T. Schmidt, L. Schulz
PSI, Villigen PSI, Switzerland
|
|
|
The development of the U15 undulator was presented at the MEDSI Conference 2012 in Shanghai. Meanwhile the undulator line is finished. The presentation will explain the experience with the production, the assembling and the commissioning of the undulators. We succeeded to implement a robotic system, that did the final adjustment of all the magnets automatically. Therefore, we were able to reduce the time for the adjustment of the magnets dramatically. A whole loop with measuring, adjustment of the columns and final adjustment with the robotic system for the magnets takes 3 days. The presentation will explain these steps. For the next beam-line, we will profit from the experience of the U15 undulator development, but there are new requirements, because it will be a polarized undulator with a period of 38mm. We are developing a new arrangement of the drives, a further development of the magnet keepers and a vacuum-pipe with only 0.2mm of wall thickness.
|
|
|
Slides WECA03 [11.263 MB]
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-MEDSI2016-WECA03
|
|
About • |
paper received ※ 09 September 2016 paper accepted ※ 16 September 2016 issue date ※ 22 June 2017 |
|