Author: Zhou, J.X.
Paper Title Page
THPO028 Magnetic Field Measurement and Analysis for Drift Tube Linac of CSNS 738
 
  • B. Li, M.X. Fan, A.H. Li, P.H. Qu, Y. Wang, X.L. Wu
    CSNS, Guangdong Province, People’s Republic of China
  • Q. Chen, K.Y. Gong, W. Kang, H.C. Liu, J.X. Zhou
    IHEP, Beijing, People’s Republic of China
 
  Funding: The National Natural Science Foundation of China(11105166); Youth Innovation Promotion Association(2015011)
A 324MHz Alvarez-type Drift Tube Linac (DTL) is used to accelerate the H ion beam from 3 to 80 MeV with peak current 15mA for China Spallation Neutron Source (CSNS). DTL is composed by 36 meters cavity and 161 DTs, the DT magnet coil adopted SAKAE structure with compact, smaller aperture. Magnetic field is measured by self-developed high precision rotating coil measurement system. This paper introduces the rotating coil measure-ment system simply and presents the 161 DTs magnetic field measurement results comprehensively, include mag-netic field center offset, integral magnetic field, higher-order harmonics. In addition, cooling test result of magnet coil is also presented.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2018-THPO028  
About • paper received ※ 31 August 2018       paper accepted ※ 20 September 2018       issue date ※ 18 January 2019  