Author: Yang, H.
Paper Title Page
TUPO088 Measurement of Diagnostics Response by RF Parameters for Hard X-ray Line in PAL-XFEL* 531
 
  • H. Yang
    PAL, Pohang, Kyungbuk, Republic of Korea
 
  Funding: *This work is supported by MSIP, Korea.
PAL-XFEL is a hard x-ray (HX) and soft x-ray (SX) FEL machine to generate 2.5 - 15 keV FEL in the HX line and 0.28 - 1.2 keV FEL in the SX line. The HX line consists of an e-gun, a laser heater, S-band accelerators, an X-band linearizer, three bunch compressors (BC), and a dog-leg line. PAL-XFEL maintains the stable operation and FEL delivery with more than 98% availability due to machine stabilities including RF modules. In order to investigate the stable operation, we measure the diagnostics response for bunch charge monitors, energy beam position monitors, bunch length monitors, and a FEL intensity with a photon beam position monitor by RF parameters - RF amplitude and phase for an e-gun, accelerators, and a linearizer. In this paper, we present mainly corresponding RF parameters for e-beam and FEL jitters by this measurement and matrix analysis.
 
poster icon Poster TUPO088 [0.281 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2018-TUPO088  
About • paper received ※ 11 September 2018       paper accepted ※ 19 September 2018       issue date ※ 18 January 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)