Author: Tamura, J.
Paper Title Page
THPO048 Low Power Measurement of a 1300-MHz RFQ Cold Model 794
THOP02   use link to see paper's listing under its alternate paper code  
 
  • Y. Kondo, T. Morishita, J. Tamura
    JAEA/J-PARC, Tokai-mura, Japan
  • M. Otani
    KEK, Ibaraki, Japan
 
  Funding: This work is supported by JSPS KAKENHI Grant Number 17K18784.
A muon linac development for a new muon g-2/EDM experiment is now going on at J-PARC. Muons from the muon beam line (H-line) of the J-PARC muon facility are once stopped in a silica aerojel target and room temperature muoniums are evaporated from the aerogel. They are dissociated with the lasers to be the ultra slow muons, then accelerated up to 212 MeV using a linear accelerator. The low energy part of this muon linac consists of a 324-MHz RFQ and an IH DTL. The frequency is increased to 1296 MHz at the following CCL section. We propose to replace the low energy section to a 1300-MHz RFQ to simplify the configuration of the muon linac. The 1300-MHz RFQ will be extremely small compared to conventional RFQs, therefore we made a cold model to proof the feasibility of this scheme. In this paper, the result of low-power measurement of the 1300-MHz RFQ cold model is described.
 
slides icon Slides THPO048 [2.160 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2018-THPO048  
About • paper received ※ 12 September 2018       paper accepted ※ 20 September 2018       issue date ※ 18 January 2019  