Author: Takeishi, K.
Paper Title Page
TUPO065 Improvement of Cavity Performance by Nitrogen Doping at KEK 480
SPWR019   use link to see paper's listing under its alternate paper code  
 
  • T. Okada, Y. Hori, E. Kako, T. Konomi, H. Sakai, K. Umemori, Y. Yamamoto
    Sokendai, Ibaraki, Japan
  • T. Dohmae, Y. Hori, E. Kako, T. Konomi, T. Saeki, T. Saeki, H. Sakai, K. Umemori, Y. Yamamoto
    KEK, Ibaraki, Japan
  • J. Kamiya
    JAEA/J-PARC, Tokai-mura, Japan
  • S. Kurosawa, K. Takeishi
    JAEA, Ibaraki-ken, Japan
 
  Nitrogen doping experiments in single-cell and 3-cell niobium cavities were carried out at KEK. After annealing at 800 deg C for 3 hours, pure nitrogen gas with a pressure of 3 Pa for 20 minutes and 3 minutes were introduced for doping in a furnace in J-PARC, respectively. Removing surface in 5 um and 20 um by electropolishing were performed prior to the vertical tests, respectively. Increases of a quality factor at 2K and reduction of the BCS resistance with respect to an accelerating gradient were observed in both cavities.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2018-TUPO065  
About • paper received ※ 12 September 2018       paper accepted ※ 21 September 2018       issue date ※ 18 January 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPO071 Study on Nitrogen Infusion for 1.3 GHz SRF Cavities Using J-PARC Furnace 499
 
  • K. Umemori, T. Dohmae, M. Egi, Y. Hori, E. Kako, T. Konomi, S. Michizono, T. Saeki, H. Sakai, Y. Yamamoto
    KEK, Ibaraki, Japan
  • J. Kamiya
    JAEA/J-PARC, Tokai-mura, Japan
  • S. Kurosawa, K. Takeishi
    JAEA, Ibaraki-ken, Japan
  • T. Okada
    Sokendai, Ibaraki, Japan
 
  Nitrogen infusion (N-infusion) is new surface treatment technique for niobium SRF (Superconducting RF) cavities. After cooling down from 800 degree C heat treatment, a vacuum furnace and cavities are kept 120 degree C, 48 hours with about 3 Pa Nitrogen. Improvement of Q-value and accelerating gradient is expected. We used J-PARC furnace, since N-infusion procedure requires clean vacuum furnace. It has a cryo-pump and turbo molecular pumps and its vacuum system is oil-free system. Six times of N-infusion tests were carried out, while changing vacuum condition, N-infusion temperature, Nitrogen pressure, niobium material and so on. Niobium caps were mounted on cavities to avoid contaminations on inner surfaces. Some of trials were successful and vertical test results showed improvement of Q-values and accelerating gradient. However, some of them were not. Most of bad cases showed degradation of Q-values above 5 MV/m. Details of heat treatment procedure including N-infusion and vertical test results are shown in this presentation.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2018-TUPO071  
About • paper received ※ 20 September 2018       paper accepted ※ 20 September 2018       issue date ※ 18 January 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)