Paper |
Title |
Page |
MOPO100 |
Doubly Stripped Proton Causing Vacuum Leak at Brookhaven 200 MeV H− linac Complex |
214 |
|
- D. Raparia, G. Atoian, T. Lehn, V. LoDestro, M. Mapes, A. McNerney, J. Ritter, A. Zelenski
BNL, Upton, Long Island, New York, USA
|
|
|
Doubly stripped H− in the low energy beam transport are capture 180 degree apart in the RF of RFQ and accelerated to the full energies. These protons are bend in the opposite direction of H− after the 200 MeV drift tube linac and caused vacuum leak. A new beam dump for these stripped protons is planned
|
|
|
Poster MOPO100 [4.781 MB]
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2018-MOPO100
|
|