Author: LoDestro, V.
Paper Title Page
MOPO100 Doubly Stripped Proton Causing Vacuum Leak at Brookhaven 200 MeV H linac Complex 214
 
  • D. Raparia, G. Atoian, T. Lehn, V. LoDestro, M. Mapes, A. McNerney, J. Ritter, A. Zelenski
    BNL, Upton, Long Island, New York, USA
 
  Doubly stripped H in the low energy beam transport are capture 180 degree apart in the RF of RFQ and accelerated to the full energies. These protons are bend in the opposite direction of H after the 200 MeV drift tube linac and caused vacuum leak. A new beam dump for these stripped protons is planned  
poster icon Poster MOPO100 [4.781 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2018-MOPO100  
About • paper received ※ 11 September 2018       paper accepted ※ 20 September 2018       issue date ※ 18 January 2019  