MOPO063 Development of Side-coupled X-band Medical Linear Accelerator for Radiotherapy 139
 
  • Y.S. Lee, Y.W. Choi, G.J. Kim, I.S. Kim, J.I. Kim, S. Kim, J.H. Lee
    KERI, Changwon, Republic of Korea
  • J.H. Hwang, Y.N. Kang, A.R. Kim, J.N. Kim, T.G. Oh, Y.A. Oh, Y. J. Seol, J.S. Shin
    The Catholic University of Korea, Seoul, Republic of Korea
 
  Recently, LINAC-based radiotherapy equipment are being developed by combining with imaging devices such as CT or MRI, so that it is possible to precisely focus high dose radiation on tumor tissues while minimizing the normal tissue damage. In order to place the diagnostic and treatment devices simultaneously in a confined space, constraints related to interference and volume between the subsystems must be considered. To meet these requirements, the size and weight of the LINAC system need to be reduced, which can be achieved by applying X-band technology. For the purpose of use in IMRT based on image guided radiotherapy, we developed a 9.3 GHz X-band medical LINAC using side-coupled structure. The LINAC is designed to have the accelerating field strength of 16.8 MV/m, and the beam current transmission efficiency of 26 % at the end of accelerating cell when the supplied RF power is at 1.7 MW. Therefore, it can accelerate the electron beam up to 6.2 MeV with having about 90 mA beam current. We plan to carry out the performance test using beam diagnostics system and X-ray measurement system, and the details of design and experimental results of LINAC will be described in this paper.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2018-MOPO063  
About • paper received ※ 12 September 2018       paper accepted ※ 19 September 2018       issue date ※ 18 January 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPO064 O-Arm Mounted X-Band Linear Accelerator System for Radiotherapy 142
 
  • S. Kim, Y.W. Choi, G.J. Kim, I.S. Kim, J.I. Kim, J.H. Lee, Y.S. Lee
    KERI, Changwon, Republic of Korea
  • J.H. Hwang, Y.N. Kang, A.R. Kim, J.N. Kim, T.G. Oh, Y.A. Oh, Y. J. Seol, J.S. Shin
    The Catholic University of Korea, Seoul, Republic of Korea
 
  Current advances in radiotherapy are based on the precise imaging techniques, and there is a pressing need for the development of techniques that are capable of visualizing cancer tissues in real time in conjunction with radiotherapy. Indeed, the image-guided radiotherapy systems in which conventional diagnostic tools such as CT and MRI are combined with the linear accelerator (LINAC)-based radiotherapy have been extensively studied. In this work, we mounted 9.3GHz X-band LINAC designed by KERI on the 360 degree-rotatable O-arm system, which allows efficient integration of a diagnostic tool with a radiotherapy equipment. After mounting, the X-ray profile and percentage depth dose were measured by following the quality assurance using the AAPM TG-51,142 protocol. The beam profile symmetry was estimated to be 102.4% with ±3% tolerance. The X-ray dose was also measured by rotating the O-arm to confirm the stability of the mounted X-band LINAC. As a result, the standard deviation of the X-ray dose was shown to be 0.016 while rotating. Therefore, we demonstrate the feasibility of our O-arm X-band LINAC system for use in highly effective radiotherapy with simultaneous CT image guidance.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2018-MOPO064  
About • paper received ※ 11 September 2018       paper accepted ※ 20 September 2018       issue date ※ 18 January 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)