Author: Kasaei, S.
Paper Title Page
TUPO119 A Diagnostics Box for the Linear Accelerator of Institute for Research in Fundamental Science (IPM) 581
 
  • S. Sanaye Hajari, M. Bahrami, H. Behnamian, S. Kasaei, H. Shaker
    IPM, Tehran, Iran
  • S. Ahmadiannamin
    ILSF, Tehran, Iran
  • F. Ghasemi
    NSTRI, Tehran, Iran
 
  The IPM linac is an 8 MeV (up gradable to 11 MeV) electron linear accelerator under development at Institute for Research in Fundamental Sciences, Tehran, Iran. The design and construction of the linac is nearly finished and it is in the commissioning stage. The commissioning is planned in several phase of different energy ranging from 50 keV to 8 MeV. At each phase appropriate diagnostics is required in order to investigate the linac performance. A diagnostics box including a scintillator view screen, a dipole magnet, and a focusing solenoid is designed to diagnose the beam longitudinal and transverse parameters in wide range of energy. These parameters are the beam transverse profile, size, position, emittance and the energy spectrum.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2018-TUPO119  
About • paper received ※ 12 September 2018       paper accepted ※ 08 October 2018       issue date ※ 18 January 2019  