Paper |
Title |
Page |
THPO022 |
Development Progress of the H+/H− Linear Accelerators at Tsinghua University |
732 |
THOP06 |
|
|
- Q.Z. Xing, C.B. Bi, C. Cheng, C.T. Du, T.B. Du, X. Guan, Q.K. Guo, Y. Lei, P.F. Ma, S. Shuai, R. Tang, X.W. Wang, X.D. Xudong, H.Y. Zhang, S.X. Zheng
TUB, Beijing, People’s Republic of China
- W.Q. Guan, Y. He, J. Li
NUCTECH, Beijing, People’s Republic of China
- W.L. Liu, B.C. Wang, Z.M. Wang, Y. Yang, C. Zhao
NINT, Shannxi, People’s Republic of China
|
|
|
We present, in this paper, the development progress of the 13MeV proton linac for the Compact Pulsed Hadron Source (CPHS), and the 7MeV H− linac injector for the synchrotron of the Xi’an 200MeV Proton Application Facility (XiPAF).
|
|
|
Slides THPO022 [4.421 MB]
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2018-THPO022
|
|
About • |
paper received ※ 12 September 2018 paper accepted ※ 20 September 2018 issue date ※ 18 January 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPO033 |
The Development of Permanent Magnet Quadrupoles for Xipaf DTL |
753 |
|
- B.C. Wang, M.T. Qiu, Z.M. Wang, C.Y. Wei
NINT, Shannxi, People’s Republic of China
- C.T. Du, Q.K. Guo, X.W. Wang, Q.Z. Xing, S.X. Zheng
TUB, Beijing, People’s Republic of China
|
|
|
Permanent magnet quadrupoles (PMQs) are developed for the DTL of Xi’an 200 MeV Proton Application Facility (XiPAF). In this paper, we describe the fabrication and measurements for the Halbach-type PMQs. The main procedure of the PMQ manufacture is presented. And the magnetic measurements of PMQs are carried out with the help of vibrating wire, Hall probe and rotating coil respectively. The results show the PMQs are able to meet the requirements of XiPAF DTL.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2018-THPO033
|
|
About • |
paper received ※ 10 September 2018 paper accepted ※ 20 September 2018 issue date ※ 18 January 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPO036 |
Error Study of CPHS DTL after Assembly |
763 |
SPWR014 |
|
|
- P.F. Ma, C.T. Du, X. Guan, Q.K. Guo, Y. Lei, R. Tang, X.W. Wang, Q.Z. Xing, S.X. Zheng
TUB, Beijing, People’s Republic of China
- B.C. Wang
NINT, Shannxi, People’s Republic of China
|
|
|
The Compact Pulsed Hadron Source (CPHS) at Tsinghua University is one multi-purpose pulsed neutron source. The injector of the CPHS is a linac, which mainly consists of a source, a low-energy beam transport line (LEBT), a radio frequency quadrupole (RFQ) and a drift tube linac (DTL). The error study of the DTL for CPHS is presented in this paper. The error study can provide the field tolerances in the DTL cavity and the alignment tolerance between the RFQ and DTL.
|
|
|
Poster THPO036 [2.645 MB]
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2018-THPO036
|
|
About • |
paper received ※ 06 September 2018 paper accepted ※ 20 September 2018 issue date ※ 18 January 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPO064 |
Tuning of a Four-vane RFQ for Xi’an 200 MeV Proton Application Facility |
838 |
|
- X.D. Yu, X. Guan, Q.K. Guo, Y. Lei, P.F. Ma, X.W. Wang, Q.Z. Xing, S.X. Zheng
TUB, Beijing, People’s Republic of China
- B.C. Wang, Z.M. Wang, C. Zhao
NINT, Shannxi, People’s Republic of China
|
|
|
This paper mainly describes the procedures and results of tuning a four-vane Radio Frequency Quadrupole (RFQ) accelerator for the Xi’an 200 MeV Proton Application Facility (XiPAF) project. The 3-meter-long RFQ will accelerate a 50 keV H− beam from the ECR source to 3 MeV, and deliver it to the downstream drift tube linac (DTL) with a peak current of 5 mA, pulse length of 10-40 μs and maximum repetition rate of 0.5. The machining, assembly, and RF tuning of the RFQ cavity has been completed successfully. After tuning, the relative error of the operating quadrupole mode field is within ±2.7%, and the dipole mode com-ponent is within ±1.9% of the quadrupole mode. The RFQ now is ready for high-power RF conditioning.
|
|
|
Poster THPO064 [1.413 MB]
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2018-THPO064
|
|
About • |
paper received ※ 12 September 2018 paper accepted ※ 20 September 2018 issue date ※ 18 January 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|