Paper |
Title |
Page |
MOPO118 |
Optimized Design for a Compact Linac with Collinear Absorbing Loads at the Hust FEL-THz |
242 |
SPWR029 |
|
|
- J. Jiang, G. Feng, T. Hu, Y. Lu, X.D. Tu, Y.Q. Xiong
HUST, Wuhan, People’s Republic of China
- Y.J. Pei
USTC/NSRL, Hefei, Anhui, People’s Republic of China
|
|
|
To meet the requirement of miniaturization for high power THz radiation in the field of commercial and civil use, RF Linacs have been applied widely as beam injectors, and the Linac with collinear absorbing loads reveals the potential to achieve a tradeoff between performance and compactness. Under overall consideration of systematic conflicts, optimization choices for such Linacs involving power absorbing ability, accelerating efficiency, as well as beamline length were described in this context. Meanwhile, cold testing has been conducted to verify design parameters for the collinear absorbing loads. Furthermore, elaborated calculation of thermal power loss and integrated helical water channel cooling has been performed for the 14MeV Linac with collinear absorbing loads installed on the HUST FEL-THz, and online experiments demonstrated that both the accelerating efficiency and the water cooling performance fulfilled operation demands.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2018-MOPO118
|
|
About • |
paper received ※ 11 September 2018 paper accepted ※ 20 September 2018 issue date ※ 18 January 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
MOPO119 |
Design of a Fully Automated Test Bench for Measuring the Field Distribution in Standing Wave Cavity |
246 |
|
- Y. Lu, G. Feng, T. Hu, J. Jiang, X.D. Tu, Y.Q. Xiong
HUST, Wuhan, People’s Republic of China
|
|
|
The resonant cavity plays a great role in the linear accelerator. An accurate measurement of the cavity field distribution is very important to design linear accelerators. A fully computer controlled bench for the electric field distribution has been developed in this context. Based on the perturbation theory, the acquisition of the resonant frequency shift is proportional to the square of E (electric field). In order to verify the reliability of the test bench, a standard cylindrical cavity has been tested in this measurement system. The simulation by HFSS (High Frequency Structure Simulator) and the practice will be both presented in this paper. And the result demonstrates that, because of its high concentricity, the automated test bench achieves high precision in measuring the distribution of electric field.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2018-MOPO119
|
|
About • |
paper received ※ 11 September 2018 paper accepted ※ 20 September 2018 issue date ※ 18 January 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|