Author: Behnamian, H.
Paper Title Page
TUPO119 A Diagnostics Box for the Linear Accelerator of Institute for Research in Fundamental Science (IPM) 581
 
  • S. Sanaye Hajari, M. Bahrami, H. Behnamian, S. Kasaei, H. Shaker
    IPM, Tehran, Iran
  • S. Ahmadiannamin
    ILSF, Tehran, Iran
  • F. Ghasemi
    NSTRI, Tehran, Iran
 
  The IPM linac is an 8 MeV (up grad­able to 11 MeV) elec­tron lin­ear ac­cel­er­a­tor under de­vel­op­ment at In­sti­tute for Re­search in Fun­da­men­tal Sci­ences, Tehran, Iran. The de­sign and con­struc­tion of the linac is nearly fin­ished and it is in the com­mis­sion­ing stage. The com­mis­sion­ing is planned in sev­eral phase of dif­fer­ent en­ergy rang­ing from 50 keV to 8 MeV. At each phase ap­pro­pri­ate di­ag­nos­tics is re­quired in order to in­ves­ti­gate the linac per­for­mance. A di­ag­nos­tics box in­clud­ing a scin­til­la­tor view screen, a di­pole mag­net, and a fo­cus­ing so­le­noid is de­signed to di­ag­nose the beam lon­gi­tu­di­nal and trans­verse pa­ra­me­ters in wide range of en­ergy. These pa­ra­me­ters are the beam trans­verse pro­file, size, po­si­tion, emit­tance and the en­ergy spec­trum.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2018-TUPO119  
About • paper received ※ 12 September 2018       paper accepted ※ 08 October 2018       issue date ※ 18 January 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)