Author: Ayvazyan, V.
Paper Title Page
MOPO038 RF Operation Experience at the European XFEL 109
MOOP09   use link to see paper's listing under its alternate paper code  
 
  • J. Branlard, V. Ayvazyan, Ł. Butkowski, M.K. Grecki, M. Hierholzer, M.G. Hoffmann, M. Hoffmann, M. Killenberg, D. Kostin, T. Lamb, L. Lilje, U. Mavrič, M. Omet, S. Pfeiffer, R. Rybaniec, H. Schlarb, Ch. Schmidt, N. Shehzad, V. Vogel, N. Walker
    DESY, Hamburg, Germany
 
  After its successful commissioning which took place during the first half of 2017, the European X-ray free electron laser is in now in regular operation delivering photons to users since September 2017. This paper presents an overview on the experience gathered during the first couple of years of operation. In particular, the focus is set on RF operation, maintenance activities, availability and typical failures. A first look on machine performance in terms of RF and beam stability, energy reach, radiation related investigations and microphonics studies will also be presented.  
slides icon Slides MOPO038 [2.421 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2018-MOPO038  
About • paper received ※ 11 September 2018       paper accepted ※ 20 September 2018       issue date ※ 18 January 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPO104 LLRF R&D Towards CW Operation of the European XFEL 223
SPWR026   use link to see paper's listing under its alternate paper code  
 
  • A. Bellandi, V. Ayvazyan, J. Branlard, C. Gumus, S. Pfeiffer, K.P. Przygoda, R. Rybaniec, H. Schlarb, Ch. Schmidt, J.K. Sekutowicz
    DESY, Hamburg, Germany
  • W. Cichalewski
    TUL-DMCS, Łódź, Poland
 
  The ever growing request for machines with a higher average beam pulse rate and also with a relaxed (< 1 MHz) pulse separation calls for superconducting linacs that operate in Long Pulse (LP) or Continuous Wave (CW) mode. For this purpose the European X-ray Free Electron Laser (European XFEL) could be upgraded to add the ability to run in CW/LP mode. Cryo Module Test Bench (CMTB) is a facility used to perform tests on superconducting cavity cryomodules. Because of the interest in upgrading European XFEL to a CW machine, CMTB is now used to perform studies on XM-3, a 1.3 GHz European XFEL-like cryomodule with modified coupling that is able to run with very high quality factor (QL = 10E7…10E8) values. The RF power source allows running the cavities at gradients larger than 16 MV/m. Because of the QL and gradient values involved in these tests, detuning effects like mechanical resonances and microphonics became more challenging to regulate. The goal is then to determine the appropriate set of parameters for the LLRF control system to keep the error to be less than 0.01° in phase and 0.01% in amplitude.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2018-MOPO104  
About • paper received ※ 11 September 2018       paper accepted ※ 20 September 2018       issue date ※ 18 January 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPO029 Highlights of the XM-3 Cryomodule Tests at DESY 388
 
  • J. Branlard, V. Ayvazyan, A. Bellandi, J. Eschke, C. Gumus, D. Kostin, K.P. Przygoda, H. Schlarb, J.K. Sekutowicz
    DESY, Hamburg, Germany
  • W. Cichalewski
    TUL-DMCS, Łódź, Poland
 
  To investigate the feasibility of the continuous wave (cw) upgrade of the European XFEL (E-XFEL) DESY, on-going tests are performed on E-XFEL prototype and production cryomodules since 2011. For these studies, DESY’s Cryo-Module Test Bench (CMTB) has been equipped with a 105 kW cw operating IOT in addition to the 10MW pulsed klystron, making CMTB a very flexible test stand, enabling both cw and pulse operation. For these tests, E-XFEL-like LLRF electronics is used to stabilize amplitude and phase of the voltage Vector Sum (VS) of all 8 cavities of the cryomodule under test. The cryomodule most often tested is the pre-series XM-3, unique since it is housing one fine grain niobium and seven large grain niobium cavities. In autumn 2017, additional spacers were installed on all 8 input couplers to increase the maximum reachable loaded quality factor Ql beyond 2·107. With higher Ql, up to 6·107 for 6 cavities and 2.7·107 for 2 cavities, we have investigated the VS stability and SRF-performance of this cryomodule under various conditions of cooling down rate and operation temperature 1.65K, 1.8K and 2K, at gradients up to ca. 18MV/m. The results of these tests are presented in this paper.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2018-TUPO029  
About • paper received ※ 11 September 2018       paper accepted ※ 20 September 2018       issue date ※ 18 January 2019  