Author: Hori, Y.
Paper Title Page
WEPGW037 Development of a Dense Gas Sheet Target for a 2D Beam Profile Monitor 2554
 
  • N. Ogiwara, Y. Hori
    J-PARC, KEK & JAEA, Ibaraki-ken, Japan
  • Y. Hikichi, J. Kamiya, M. Kinsho
    JAEA/J-PARC, Tokai-Mura, Naka-Gun, Ibaraki-Ken, Japan
  • I. Yamada
    Doshisha University, Graduate School of Engineering, Kyoto, Japan
 
  We have been developing a dense gas sheet target to realize a non-destructive and fast-response beam profile monitor for the accelerators in J-PARC. The beaming effect in vacuum science and technology has been employed for making a gas sheet. The gas sheet with a thickness of ~ 1 mm and the density of 2 x 10-4 Pa was successfully obtained. Then, we have successfully measured the profiles of the 400 MeV H ion beam in J-PARC linac by detecting the ions generated through the collision of this gas sheet to the H beam. This time, we have developed the gas sheet with the density of more than 10-3 Pa using a circular slit. The details of the new gas sheet generator will be shown.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-WEPGW037  
About • paper received ※ 20 May 2019       paper accepted ※ 23 May 2019       issue date ※ 21 June 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPGW030 Beam Profile Monitor for Slow Extracted Beam Using Multi-Layered Graphene at J-PARC 2532
 
  • Y. Hashimoto, Y. Hori, R. Muto, M. Tomizawa, T. Toyama, M. Uota
    KEK, Tokai, Ibaraki, Japan
  • M. Endo, H. Sakai
    Mitsubishi Electric System & Service Co., Ltd, Tsukuba, Japan
  • M. Murakami, K. Murashima, M. Tachibana, A. Tatami
    KANEKA, Osaka, Japan
 
  Extracted-beam profiles in slow extraction at J-PARC has been measured by using secondary electrons emitted from a target array made by multi-layered graphen, in real time during spill time of around 2 seconds. The target array consists of 20 ribbons with width of 1 mm, pitch of 2 mm, and thickness of 1.1 micron. Secondary-electron current at each channel is measured by a current amplifier having sensitivity more than 1 pA. These configuration produces useful information for beam dynamics in slow extraction. We have set this monitor at the entrance of a septum magnet, then we can also measure the last few-turns beam with the extracted beam simultaneously. We will discuss about features of this instrument and recent beam study with 51 kW extracted-beams.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-WEPGW030  
About • paper received ※ 15 May 2019       paper accepted ※ 21 May 2019       issue date ※ 21 June 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)