JACoW logo

Joint Accelerator Conferences Website

The Joint Accelerator Conferences Website (JACoW) is an international collaboration that publishes the proceedings of accelerator conferences held around the world.


RIS citation export for THPTS002: Sirius Pre-alignment Results

TY  - CONF
AU  - Junqueira Leão, R.
AU  - Geraissate Paranhos de Oliveira, H.
AU  - Rodrigues, F.
AU  - Rovigatti de Oliveira, G.R.
AU  - Sposito, U.R.
ED  - Boland, Mark
ED  - Tanaka, Hitoshi
ED  - Button, David
ED  - Dowd, Rohan
ED  - Schaa, Volker RW
ED  - Tan, Eugene
TI  - Sirius Pre-alignment Results
J2  - Proc. of IPAC2019, Melbourne, Australia, 19-24 May 2019
CY  - Melbourne, Australia
T2  - International Particle Accelerator Conference
T3  - 10
LA  - english
AB  - Sirius is a 4th generation synchrotron light source under final installation and beginning of commissioning phase in Brazil, with a bare emittance of 250 picometer rad. In order to fulfil stability requirements (magnets displacement caused by vibration of 6 nm) imposed to achieve expected performance, the mechanical assembly of supporting structures and magnets were designed without adjustment mechanisms. Yet, the misalignment errors of the magnets are the dominating source of dynamical aperture reduction, leading to a maximum permissible deviation of 40 micrometers between adjacent magnets. To this end, dimensional engineering was applied to conceive an alignment concept for magnets on a same girder based solely on the geometric characteristics of the parts. For the large volume positioning of girders in the storage ring tunnel, the applied methodology followed a strategy optimized to reduce measurement uncertainty, as described in the literature. This paper will present the complete measurement process that led to the alignment of Sirius, from the deployment and survey of reference networks to the final alignment of the machine. To express a consistent and unequivocal alignment result and assess the alignment quality considering the measurement uncertainty, an innovative metric described previously was employed. This work will show that the positioning of supports satisfies the requirement of 80 micrometer between girders. Also, the devices and mechanisms used for assembling will be detailed. Inspection of full girder set performed on a Coordinate measuring machine shows a maximum deviation of 30 micrometers for any pair of magnets on a common support.
PB  - JACoW Publishing
CP  - Geneva, Switzerland
SP  - 4106
EP  - 4108
KW  - alignment
KW  - booster
KW  - storage-ring
KW  - network
KW  - laser
DA  - 2019/06
PY  - 2019
SN  - 978-3-95450-208-0
DO  - DOI: 10.18429/JACoW-IPAC2019-THPTS002
UR  - http://jacow.org/ipac2019/papers/thpts002.pdf
ER  -