The Joint Accelerator Conferences Website (JACoW) is an international collaboration that publishes the proceedings of accelerator conferences held around the world.
TY - CONF AU - Junqueira Leão, R. AU - Geraissate Paranhos de Oliveira, H. AU - Rodrigues, F. AU - Rovigatti de Oliveira, G.R. AU - Sposito, U.R. ED - Boland, Mark ED - Tanaka, Hitoshi ED - Button, David ED - Dowd, Rohan ED - Schaa, Volker RW ED - Tan, Eugene TI - Sirius Pre-alignment Results J2 - Proc. of IPAC2019, Melbourne, Australia, 19-24 May 2019 CY - Melbourne, Australia T2 - International Particle Accelerator Conference T3 - 10 LA - english AB - Sirius is a 4th generation synchrotron light source under final installation and beginning of commissioning phase in Brazil, with a bare emittance of 250 picometer rad. In order to fulfil stability requirements (magnets displacement caused by vibration of 6 nm) imposed to achieve expected performance, the mechanical assembly of supporting structures and magnets were designed without adjustment mechanisms. Yet, the misalignment errors of the magnets are the dominating source of dynamical aperture reduction, leading to a maximum permissible deviation of 40 micrometers between adjacent magnets. To this end, dimensional engineering was applied to conceive an alignment concept for magnets on a same girder based solely on the geometric characteristics of the parts. For the large volume positioning of girders in the storage ring tunnel, the applied methodology followed a strategy optimized to reduce measurement uncertainty, as described in the literature. This paper will present the complete measurement process that led to the alignment of Sirius, from the deployment and survey of reference networks to the final alignment of the machine. To express a consistent and unequivocal alignment result and assess the alignment quality considering the measurement uncertainty, an innovative metric described previously was employed. This work will show that the positioning of supports satisfies the requirement of 80 micrometer between girders. Also, the devices and mechanisms used for assembling will be detailed. Inspection of full girder set performed on a Coordinate measuring machine shows a maximum deviation of 30 micrometers for any pair of magnets on a common support. PB - JACoW Publishing CP - Geneva, Switzerland SP - 4106 EP - 4108 KW - alignment KW - booster KW - storage-ring KW - network KW - laser DA - 2019/06 PY - 2019 SN - 978-3-95450-208-0 DO - DOI: 10.18429/JACoW-IPAC2019-THPTS002 UR - http://jacow.org/ipac2019/papers/thpts002.pdf ER -