JACoW logo

Joint Accelerator Conferences Website

The Joint Accelerator Conferences Website (JACoW) is an international collaboration that publishes the proceedings of accelerator conferences held around the world.


RIS citation export for WEPAF053: Status and Commissioning of the European XFEL Beam Loss Monitor System

TY - CONF
AU - Wamsat, T.
AU - Lensch, T.
AU - Smirnov, P.A.
ED - Koscielniak, Shane
ED - Satogata, Todd
ED - Schaa, Volker RW
ED - Thomson, Jana
TI - Status and Commissioning of the European XFEL Beam Loss Monitor System
J2 - Proc. of IPAC2018, Vancouver, BC, Canada, April 29-May 4, 2018
C1 - Vancouver, BC, Canada
T2 - International Particle Accelerator Conference
T3 - 9
LA - english
AB - The European XFEL MTCA based Beam Loss Monitor System (BLM) is composed of about 450 monitors, which are part of the Machine Protection System (MPS). The BLMs detect losses of the electron beam, in order to protect accelerator components from damage and excessive activation, in particular the undulators, since they are made of permanent magnets. Also each cold accelerating module is equipped with a BLM to measure the sudden onset of field emission (dark current) in cavities. In addition some BLMs are used as detectors for wire- scanners. Experience from the already running BLM system in FLASH2 which is based on the same technology, led to a fast implementation of the system in the XFEL. Further firmware and server developments related to alarm generation and handling are ongoing. The BLM systems structure, the current status and the different possibilities to trigger alarms which stop the electron beam will be presented.
PB - JACoW Publishing
CP - Geneva, Switzerland
SP - 1940
EP - 1943
KW - FEL
KW - electron
KW - high-voltage
KW - controls
KW - hardware
DA - 2018/06
PY - 2018
SN - 978-3-95450-184-7
DO - 10.18429/JACoW-IPAC2018-WEPAF053
UR - http://jacow.org/ipac2018/papers/wepaf053.pdf