JACoW logo

Joint Accelerator Conferences Website

The Joint Accelerator Conferences Website (JACoW) is an international collaboration that publishes the proceedings of accelerator conferences held around the world.


RIS citation export for THPML090: Optical Beam Loss Monitors Based on Fibres for the CLARA Phase 1 Beam-Line

TY - CONF
AU - Alexandrova, A.S.
AU - Brynes, A.D.
AU - Devlin, L.J.
AU - Effinger, E.
AU - Holzer, E.B.
AU - Jackson, F.
AU - Tzoganis, V.
AU - Welsch, C.P.
ED - Koscielniak, Shane
ED - Satogata, Todd
ED - Schaa, Volker RW
ED - Thomson, Jana
TI - Optical Beam Loss Monitors Based on Fibres for the CLARA Phase 1 Beam-Line
J2 - Proc. of IPAC2018, Vancouver, BC, Canada, April 29-May 4, 2018
C1 - Vancouver, BC, Canada
T2 - International Particle Accelerator Conference
T3 - 9
LA - english
AB - Fibre based Optical Beam Loss Monitors (oBLMs) are on-line devices used in-situ to measure losses along a beam-line. The technology is based on the detection of Cherenkov radiation, produced inside quartz fibres placed alongside the beampipe, from the interaction of secondary showers generated from losses hitting the vacuum pipe. This contribution presents ongoing developments of an oBLM system installed along the Compact Linear Accelerator for Research and Applications (CLARA). The oBLM system consists of 4 channels which allows for sub-metre loss resolution with two dimensional coverage along the entirety of the beam line, as opposed to conventional localised BLM systems. The system was first commissioned to measure dark current from the injector. The ability of the system to locate longitudinal positions of known beam loss locations has also been measured and has shown excellent agreement. We present measurements acquired from the detector during regular operation and during dedicated beam tests. We also discuss the incorporation of the monitor into the accelerator diagnostics system and its use in assisting accelerator characterisation and performance.
PB - JACoW Publishing
CP - Geneva, Switzerland
SP - 4869
EP - 4872
KW - electron
KW - MMI
KW - diagnostics
KW - gun
KW - cathode
DA - 2018/06
PY - 2018
SN - 978-3-95450-184-7
DO - 10.18429/JACoW-IPAC2018-THPML090
UR - http://jacow.org/ipac2018/papers/thpml090.pdf
ER -