TY - CONF AU - Cheng, C.M. AU - Chan, C.K. AU - Chang, C.-C. AU - Cheng, Y.T. AU - Chuang, J. -Y. AU - Hsiung, G.-Y. AU - Wu, L.H. AU - Yang, Y.C. ED - Koscielniak, Shane ED - Satogata, Todd ED - Schaa, Volker RW ED - Thomson, Jana TI - Effect of Ozonated Water Cleaning on Photon Stimulated Desorption in a Stainless Steel Chamber J2 - Proc. of IPAC2018, Vancouver, BC, Canada, April 29-May 4, 2018 C1 - Vancouver, BC, Canada T2 - International Particle Accelerator Conference T3 - 9 LA - english AB - Aluminium vacuum chambers cleaned with ozonated water show a reduction of residual carbon and lower surface outgassing rate after baking. We would like to investigate if stainless steel chambers show similar ef-fects. A stainless steel test chamber was cleaned by stand-ard chemical cleaning only and then compared with an-other one after immersion in 30ppm ozonated water for thirty minutes. Both samples were baked, then photon exposed and the photon desorption yields were deter-mined by vacuum gauges and residual gas analysers at the TLS 19B beamline. The test results on photon stimulated desorption yields and partial pressure variations with and without ozonated water cleaning of the stainless steel tubes will be discussed in some detail. PB - JACoW Publishing CP - Geneva, Switzerland SP - 3778 EP - 3780 KW - photon KW - vacuum KW - ECR KW - experiment KW - radiation DA - 2018/06 PY - 2018 SN - 978-3-95450-184-7 DO - 10.18429/JACoW-IPAC2018-THPAL058 UR - http://jacow.org/ipac2018/papers/thpal058.pdf ER -